README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0335(B) Principal Investigator Name: Thomas Erben Principal Investigator E-mail Address: terben@astro.uni-bonn.de Principal Investigator Telephone Number: +49-228-733646 Principal Investigator Postal Address: Thomas Erben IAEF Bonn Auf dem Huegel 71 53121 Bonn - Germany - Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 05:00 Estimated Total Execution Time (including overheads): 04:57:55 README File Submission Date: Programme Description ===================== General Overview ---------------- This is a simple imaging in three broad band filters (programs 074.A-0335(A) + 074.A-0335(B) together) of a single target (the filament ZwCL 2341+0000). The filters are the B,V,R supported by the standard calibration plan. Approved Waiver Request Summary ------------------------------- no waiver requests submitted Critical Observing Condition Constraints ---------------------------------------- Program 074.A-0335(A) obtains the primary science band for a weak gravitational lensing study. Hence, respecting the seeing constraint and obtaining the data in good focus is essential for our scientific goals later. Together with two supporting colors from 71.A-0027(B), the data will be used to distinguish foreground from background galaxies around the main target. To reach this goal, all data have to be obtained with a clear sky and some in photometric conditions to obtain a clear sequence from red elliptical galaxies of the filament. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 5 The 5 OB's are around the position Ra: 23:44:13.70; Dec: +00:16:39.00. The centers of the OB's differ by maximal 3 arcmin from this position. Nevertheless we use the same finding chart for all OB's. Several brighter objects allow an easy verification of the position (the chart is identical for programs 074.A-0335(A) + (B) as they image the same target in different filters). OB names RXJ1347_B_1 (photometric) RXJ1347_R_2 (clear) RXJ1347_V_1 (photometric) RXJ1347_V_2 (clear) RXJ1347_V_3 (clear) List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 1 To obtain an accurate bad pixel mask for our data we request 10 DARK frames a 600 sec. to be taken around the time our data are taken (the target is only visible within the specifications for around two months ESO time during P74). OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.