README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0306(B) Principal Investigator Name: Valentina D'Odorico Principal Investigator E-mail Address: dodorico@ts.astro.it Principal Investigator Telephone Number: 040 3199217 Principal Investigator Postal Address: c/o Osservatorio Astronomico di Trieste via G.B. Tiepolo, 11 34131 Trieste (Italy) Instrument: UVES OPC Priority Class: B OPC Approved Total Execution Time: 06:48:00 Estimated Total Execution Time (including overheads): 06:46:05 README File Submission Date: 24/08/2004 Programme Description ===================== General Overview ---------------- We would like to obtain spectra of QSOs at redshift 4 in order to study the chemical abundances in associated absorption systems. The main requirement is to obtain the largest signal-to-noise ratio for the spectra. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- The studied object has magnitude R=18.5. To achieve the goal of maximizing the signal-to-noise ratio the QSO should be observed when the moon is below the horizon. Both set-ups are fundamental in order to achieve our science goals. Highest priority should be given to execution of 2 OBs using the R580 set-up and 2 OBs using the Red860 set-up (all 4 of 1h each). Priorities have been also summarised below, in the "List of Science OBs" section. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) OB Name Priorities PSS1159+1337_R580_1h-1 1 PSS1159+1337_R580_1h-2 1 PSS1159+1337_R860_1h-1 1 PSS1159+1337_R860_1h-2 1 PSS1159+1337_R580_1h-3 2 PSS1159+1337_R860_1h-3 2 PSS1159+1337_R580_05h 3 Total Number of Submitted Science OBs: 7 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] Y [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.