README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0196(A) Principal Investigator Name: Kim-Vy Tran Principal Investigator E-mail Address: vy@phys.ethz.ch Principal Investigator Telephone Number: +41-1-633-3280 Principal Investigator Postal Address: Institute for Astronomy / ETH Hoenggerberg, HPF D8 / CH-8093 Zurich / Switzerland Instrument: FORS2 OPC Priority Class: B OPC Approved Total Execution Time: 40.0 hours Estimated Total Execution Time (including overheads): 39:59:32 README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- This is a blind, deep spectroscopic survey in GOODS-S/UDF that is centered in wavelength on the OH window at 9200A. Our observing strategy is slightly unorthodox but has been proven in a previous run (71.A-0681(A)); our observing strategy also has been approved by ESO for use in these OB's. The FORS2 slit mask is made of 9 parallel longslits that run North/South; we are using the same fims mask design from our previous run (also approved by ESO). The same target coordinates are used for all the OB's (03:32:35.9, -27:47:50). The OB's are divided into 5 different pointings where each pointing is made of 4x2hour OB's (also approved by ESO). The 5 pointings are offset from each other in RA by 1.8"; this enables us to map a contiguous area for each longslit that is 9" wide. Please take the OB's sequentially, i.e. UDF-1.1, UDF-1.2, UDF-1.3, UDF-1.4, UDF-2.1, UDF-2.2, UDF-2.3, UDF-2.4, UDF-3.1, etc. OB's for each pointing (e.g. UDF-1.*) should be completed before moving to the next pointing (e.g. UDF-2.*) so that we reach our target depth. We have included one calibration OB for the spectrophotometric standard star (see below for details). Completion of this OB is absolutely necessary because our grism+filter combo is not included in the standard FORS2 calibrations. Approved Waiver Request Summary ------------------------------- We have requested and been granted the following waivers: - 074.A-0196A.01.WAV: OB durations up to 2 hours. This request was granted on 17 Aug 2004. - Non-standard mask+observing strategy (see Overview) This request was granted on 24 Aug 2004. Critical Observing Condition Constraints ---------------------------------------- NONE Time Critical Aspects --------------------- NONE Special Calibration Information ------------------------------- STANDARD STAR: We have included one calibration OB to take a spectrophotometric standard of LTT 1020: 01h 54m 49.68s, -27d 28' 29.7'' V = 11.52, B-V = +0.56, Spectral type: G This OB is absolutely necessary because our grism+filter combination is not included in the standard FORS2 calibrations. The calibration OB (called "LTT 1020 standard star") begins with the normal specphot_acq_fast and specphot_cal_scrflat_fast templates but then, if at all possible, we would like to take the standard star through our mask. This requires a little finesse, but the support astronomer during our previous run was able to take the standard star through the middle slit of our mask fairly quickly. We would greatly appreciate the support astronomer's best effort attempt to take the standard star through our mask. I have included the appropriate templates (mxu_obs_slit, img_obs_crsplit, mxu_obs_slit, and mxu_obs_off) in our calibration OB. I have also added several extra templates to give the support astronomer plenty of time to correct the target coordinates; any extra templates can be discarded as the support astronomer deems fit. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- Total Number of Submitted Science OBs: 20 UDF-1.1, UDF-1.2, UDF-1.3, UDF-1.4 UDF-2.1, UDF-2.2, UDF-2.3, UDF-2.4 UDF-3.1, UDF-3.2, UDF-3.3, UDF-3.4 UDF-4.1, UDF-4.2, UDF-4.3, UDF-4.4 UDF-5.1, UDF-5.2, UDF-5.3, UDF-5.4 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 1 LTT 1020 standard star OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.