README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0138(A) Principal Investigator Name: Joerg Dietrich Principal Investigator E-mail Address: dietrich@astro.uni-bonn.de Principal Investigator Telephone Number: +49 228 733673 Principal Investigator Postal Address: IAEF Auf dem Huegel 71 53127 Bonn Germany Instrument: VIMOS OPC Priority Class: A OPC Approved Total Execution Time: 2h Estimated Total Execution Time (including overheads): 2:17 README File Submission Date: 30.07.2004 Programme Description ===================== General Overview ---------------- We plan to obtain a large spectroscopic sample of galaxies down to R=22.7 mag in the field of the two neighboring massive z=0.21 clusters A~222/223. We found evidence for a filament connecting both clusters in color-selected early-type galaxies, X-rays, and weak lensing. A large spectroscopic sample will not only allow us to study the cluster dynamics, but also the galaxy population in the cluster, filament, and field environment, thus probing a large variety of galaxy densities and environments. This could possibly provide the first spectroscopic evidence for a galaxy overdensity along a weak lensing candidate for a filament. We detect additional mass peaks in our weak lensing map, not corresponding to any previously known galaxy cluster. Our redshift samples will provide spectroscopic confirmation of these mass concentrations and allow us to determine their masses. Approved Waiver Request Summary ------------------------------- VIMOS overheads as reported by p2pp-2.8 by far exceed those listed in the VIMOS User Manual. This was reported to USG (Support Request Number USG-10751). No response was received so far (beyond the time scale on which USG promises a response). This is the reason the total execution time has to exceed the allocated time. The time critical nature of pre-imaging and my imminent summer vacation force me to submit this without USG approval. Critical Observing Condition Constraints ---------------------------------------- NONE Time Critical Aspects --------------------- NONE Special Calibration Information ------------------------------- NONE ToO Information --------------- This is not a ToO program Pre-Imaging Requirements ------------------------ This is the pre-imaging run for 074.A-0138(B) Source of preimaging: VIMOS, this run OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 12 PRE_A222_01.obx PRE_A222_02.obx PRE_A222_03.obx PRE_A222_04.obx PRE_A222_05.obx PRE_A222_06.obx PRE_A222_07.obx PRE_A222_08.obx PRE_A222_09.obx PRE_A222_10.obx PRE_A222_11.obx PRE_A222_12.obx List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.