README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0073(B) Principal Investigator Name: P. Merluzzi Principal Investigator E-mail Address: merluzzi@na.astro.it Principal Investigator Telephone Number: 39 081 5575548 Principal Investigator Postal Address: Osservatorio Astronomico di Capodimonte Via Moiariello 16 80131 Napoli, Italy Instrument: VIMOS OPC Priority Class: B OPC Approved Total Execution Time: 19.9 h Estimated Total Execution Time (including overheads): 19.9h README File Submission Date: 04-10-2004 Programme Description ===================== General Overview ---------------- The target is a cluster of galaxies at z=0.2 and the main sample is limited at R=20.5. Our aim is to obtain spectra of the target objects with a S/N at least 30 per Angstrom in order to derive the central velocity dispersions. This will be obtained with the estimated integration time provided that i) the galaxies are perfectly centered in the slits both in the dispersion and spatial direction and ii) a suitable jitter is performed. To this aim we were very careful in making the VIMOS masks and in choosing the offsets. We prepare four masks, each of them observed in three exposures lasting about 1.66 h each (see the approved waiver request 074.A-0073B.03). We ask to submit OBs longer than an hour in order to achieve an accurate sky subtraction by performing the offset along the slit. As pointed out in the VIMOS manual 1.3, for MOS observations it is highly reccomanded to observe arcs during nighttime, in order to avoid offsets due to flexures. Therefore, we include in the three exposures for each mask (e.g. MOS1A Abell209, MOS1B Abell209, MOS1C Abell209) the arc observation (VIMOS_mos_cal_NightCalib). Approved Waiver Request Summary ------------------------------- We request to submit OBs longer than one hour on 10 August 2004 and this was approuved on 11 August 2004, the waiver request ID being 074.A-0073B.03. Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Special Calibration Information ------------------------------- We submit also one OBs for each of the 12 exposures for the spectrophotometric standard observations. We would ask, in principle, to have the spectrophotometric standard (SPS) observed after the scientific exposure. Even if we provide one SPS OB for each scientific exposure, we will be happy to have SPS observations before the first and after the last scientific exposure when a series of scientific exposures are taken in the same night, i.e. start with a SPS, execute as many science OBs of the same mask as possible, end with a SPS. ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: VIMOS OB Information ============== List of Science OBs ------------------- MASK science OB SPS OB 1 MOS1A Abell209 FC MOS1A_LTT1020_FC * MOS1B Abell209 FC MOS1B_LTT1020_FC MOS1C Abell209 FC MOS1C_LTT1020_FC 2 MOS2A Abell209 FC MOS2A_LTT1020_FC MOS2B Abell209 FC MOS2B_LTT1020_FC MOS2C Abell209 FC MOS2C_LTT1020_FC 3 MOS3A Abell209 FC MOS3A_LTT1020_FC MOS3B Abell209 FC MOS3B_LTT1020_FC MOS3C Abell209 FC MOS3C_LTT1020_FC 4 MOS4A Abell209 FC MOS4A_LTT1020_FC MOS4B Abell209 FC MOS4B_LTT1020_FC MOS4C Abell209 FC MOS4C_LTT1020_FC * The spectrophotometric standard has magnitude V=11.52 and has spectral type G. Total Number of Submitted Science OBs: 24 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs:0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? Y Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? NA [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? NA [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? Y [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? Y [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.