README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.D-0771(A) Principal Investigator Name: Dietrich Baade Principal Investigator E-mail Address: dbaade@eso.org Principal Investigator Telephone Number: +49-89-3200-6388 Principal Investigator Postal Address: ESO Karl-Schwarzschild-Str. 2 D-85748 Garching b. Muenchen Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 14h Estimated Total Execution Time (including overheads): ToO README File Submission Date: Feb. 23, 2004 Programme Description ===================== General Overview ---------------- We aim for spectroplarimetry of SNe with a precision of 0.1%. These SNe are yet to be discovered. Therefore, this is a ToO project. If sufficiently bright SNe are discovered during P71, we will request observations to be repeated at intervals ranging from a couple of days to a month. Because the magnitudes and their evolution with time are not known in advance, exposure times can only be specified at the time of activation. For the same reason, the identity of the flux standards needs to be left open for the time being. We only submit one generic OB each for (1) an SN science exposure, (2) a science exposure of a spectroscopic flux standard, and (3) daytime calibrations. For each execution of an OB of type (1), we will request one execution of both (2) and (3) within two or three days. If two or more SNe can be observed within such an interval, only one standard star exposure (2) and one set of lamp calibrations (3) will be required. Often SNe are not too blue so that an order-sorting filter can be omitted in favour of an an extension of the wavelength coverage to the blue. To this end, a second OB without order-sorting filter is prepared but otherwise identical to (1), (2) and (3), respectively. Since we will select relatively bright and reasonably well isolated SNe, the OBs will be finalized without FIMS, i.e. using the "fast" template flavour. Observations of spectrophotometric standard stars are merely needed to calibrate the spectral response and so will be performed at Wollaston PA=0 only. Approved Waiver Request Summary ------------------------------- A waiver of the 1-hr limit on the execution time of single OBs was granted on Feb. 18. WaiverID: 073.D-0771A.01 Critical Observing Condition Constraints ---------------------------------------- None really. Time Critical Aspects --------------------- The first observation of each SN should be done as early as reasonably possible. The later observations can be made with an increasing level of flexibility ranging from +-1-2 to +-2-3 days. The polarization of SNe of Type Ia declines rapidly after optical maximum while the one of core-collapse SNe continues to grow until well after maximum. Accordingly, the corresponding series of observations (about 3-6 per SN) will cover different periods of time. There are no real-time requirements. Special Calibration Information ------------------------------- None. ToO Information --------------- This is a ToO programme. Pre-Imaging Requirements ------------------------ Not required. OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) #155168 SN with order-sorting filter #155169 SN WITHOUT order-sorting filter #155170 spectrophotometric standard star with order-sorting filter #155171 spectrophotometric standard star WITHOUT order-sorting filter Total Number of Submitted Science OBs: 4 List of Calibration OBs with Associated Science OBs --------------------------------------------------- #155172 FF + arc lamps with order-sorting filter #155173 FF + arc lamps WITHOUT order-sorting filter Total Number of Submitted Calibration OBs: 2 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] NA If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] Y [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] Y [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.