README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: Principal Investigator Name: K. Ohnaka Principal Investigator E-mail Address: kohnaka@mpifr-bonn.mpg.de Principal Investigator Telephone Number: +49-228-525-353 Principal Investigator Postal Address: Max-Planck-Institut fuer Radioastronomie / Auf dem Huegel 69 / D-53121 Bonn / Germany Instrument: MIDI OPC Priority Class: B OPC Approved Total Execution Time: 6.0 Estimated Total Execution Time (including overheads): 6.0 README File Submission Date: 12 July 2004 Programme Description ===================== General Overview ---------------- MIDI observation of 2 science targets, with each target measured at 3 different hour angles. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- All OBs should be carried out under thin cirrus sky conditions and seeing better than 1.2 arcsec. Time Critical Aspects --------------------- Each target is measured at 3 different hour angles, and these 3 observations for each target should be carried out as close in time as possible, preferably in one night. Special Calibration Information ------------------------------- ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 6 UT2UT3_SCI_13..15_rrsco UT2UT3_SCI_15..18_rrsco UT2UT3_SCI_18..20_rrsco UT2UT3_SCI_15..17_rslib UT2UT3_SCI_17..19_rslib UT2UT3_SCI_17..19_rslib-1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 6 UT2UT3_SCI_13..15_rrsco/UT2UT3_CAL_hd165135 UT2UT3_SCI_15..18_rrsco/UT2UT3_CAL_hd165135 UT2UT3_SCI_18..20_rrsco/UT2UT3_CAL_hd165135 UT2UT3_SCI_15..17_rslib/UT2UT3_CAL_hd129456 UT2UT3_SCI_17..19_rslib/UT2UT3_CAL_hd129456 UT2UT3_SCI_17..19_rslib-1/UT2UT3_CAL_hd129456 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.