README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.D-0109(A) Principal Investigator Name: Lundqvist Principal Investigator E-mail Address: peter@astro.su.se Principal Investigator Telephone Number: +46-8-55378518 Principal Investigator Postal Address: Dr. Peter Lundqvist, AlbaNova Science Center (SCFAB), Stockholm Observatory, Dept. of Astronomy, SE-106 91 STOCKHOLM, SWEDEN Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 10hrs Estimated Total Execution Time (including overheads): 10hrs README File Submission Date: 25.2.2004 Programme Description ===================== General Overview ---------------- This is a ToO program which attempts to detect narrow emission lines at the earliest observable phases of a supernova. The observations should be taken as soon as possible after the notification (if possible within the first week after explosion). Approved Waiver Request Summary ------------------------------- N/A Critical Observing Condition Constraints ---------------------------------------- N/A Time Critical Aspects --------------------- The number of follow-ups depends on the type of supernova, and whether we detect narrow lines in the first observation, or not. All this is accounted for in the OBs and will be specified in detail when the program is triggered. The first epoch observations for a SNIa or for a supernova with an unknown type: 6 x 1460 seconds with DIC1 (390+564) The first epoch observations for a SNII: 3 x 1350 seconds with DIC1 (390+564) 3 x 1350 seconds with DIC2 (437+860) For a SNIa the follow-up observations depend on whether or not the narrow CSM lines were detected in the first epoch. If there was a narrow line detection, the SN will be followed-up 7 and 14 days later with the following sequence of observations: 6 x 1430sec with DIC1 (390+564) If no CSM lines were detected in the first epoch, a second much deeper observation will follow as soon as possible (roughly 2 days) after the first one: 8 x 2070 seconds with DIC1 (390+564) For a SNII the first epoch observation will be followed-up 3, 7, and 14 days later with the following sequence of observations: 3 x 740 seconds with DIC1 (390+564) 3 x 740 seconds with DIC2 (437+860) Special Calibration Information ------------------------------- A spectrophotometric standard star close to the supernova should be observed with the same instrument settings as the supernova on each epoch the supernova is observed. The spectrophotometric standard star observations with DIC1 will also be carried out with a wide (3.0") slit to allow for absolute flux calibration for the science spectrum. In addition, telluric standard stars should be observed together with the deep (8 x 2070 sec) SNIa spectra such that one standard star (spectrophot. or telluric) is observed close in time and airmass to each of the science OBs. We will select suitable spectrophotometric and telluric standards, and provide the details together with the finding chart when triggering the ToO observations for a given supernova. We have attached flat field observations of 2x10sec to each OB in the first epoch type Ia SN observation and in the deep follow-up epoch for a type Ia SN in which no narrow lines were detected. This is necessary in order to obtain optimal correction for the possible instrumental effects (telluric lines arising within the spectrograph and CCD fringing). ToO Information --------------- This is a ToO program. It should be activated by a supernova which will be brighter than m=16. The PI (Lundqvist), or CoI's Leibundgut, Mattila and Sollerman, will contact the observatory when such an object has been discovered and will provide the exact coordinates. A finding chart will be provided, if available, but the offsets from the galaxy nucleus plus the brightness of the object should make the acquisition unambiguous. Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- Total Number of Submitted Science OBs: 20 NOTE: the total time of the submitted OBs exceeds the allocation by the OPC. However, we will only make use of subsets of the OBs, i.e. either follow the SNII or the SNIa branch. Each branch individually complies with the time limit given to us. The constraints for these observations are not very strict. Therefore, some of the OBs are longer than 1.0 hour. The SNII follow-up OBs are identical. They have been duplicated to make the epochs clear. All the SNIa OBs are not identical, but depend on the results from the first observation. A finding chart will be supplied with the trigger of the program. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 14 All the DIC1 and DIC2 OBs are not identical. Observations with a wide slit (3.0") have been included in some of the DIC1 OBs to allow for absolute flux calibration of the observations. OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.