README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.D-0045(B) Principal Investigator Name: Dr. Wolfgang Pietsch Principal Investigator E-mail Address: wnp@mpe.mpg.de Principal Investigator Telephone Number: +49 (89) 30000-3879 Principal Investigator Postal Address: Max-Planck-Institut für extraterrestrische Physik Postfach 1312 85741 Garching Instrument: FORS1 OPC Priority Class: B OPC Approved Total Execution Time: 2 Estimated Total Execution Time (including overheads): 0:59:35 twice=1:59:10 README File Submission Date: 19.02.2004 Programme Description ===================== General Overview ---------------- The goal of these observation is to detect an optical counterpart of an interesting x-ray source and to measure its R-I color. The object is marked in the finding charts. Due to a nearby bright star, occulting bars are used and alignment of the field is critical. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Good seeing (better than 0.6 arc sec) is needed to detect the object that is embedded in diffuse emission. Photometric conditions are not required, but good transparency is. The goal of the second set of observations is to detect variability, therefore these OBs should NOT be executed the same night as the first, 073.D-0045(A) is. These two OBs (073.D-0045(B)) can be executed the same night. If the two follow-up OBs (073.D-0045(B)) are executed together, the aquisition part of the second can be skipped as they use the same configurating, occulting bars, etc. Only the filter is different. The R-band OB is more important than the I-band. Time Critical Aspects --------------------- Not to be executed the same night as the 073.D-0045(A) OB is executed. These two OBs (073.D-0045(B)) can be executed the same night, but they don't have to be executed the same night. Executing them together saves some time as realignment is not necessary in this case (same pointing, focal plane config). Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.