README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.C-0685(A) Principal Investigator Name: Jenni Virtanen Principal Investigator E-mail Address: jenni.virtanen@helsinki.fi Principal Investigator Telephone Number: +358-9-19122802 Principal Investigator Postal Address: Observatory / P.O. Box 14 / FIN-00014 University of Helsinki / Finland Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 20h Estimated Total Execution Time (including overheads): 20h README File Submission Date: 26/02/2004 Programme Description ===================== General Overview ---------------- Astrometric recovery observations of transneptunian objects (TNOs) with large ephemeris uncertainties that have high probabilities of being in peculiar orbits. Our observing programme consists of sequences of OBs. Each sequence is connected with one target (TNO) and they are grouped under their own subfolders (named with running number starting from TNO01, TNO02, etc.). Each moving object (MOV) OB consist of one acquisition image and one science image taken without a filter. There are six identical MOV OBs for each target field for the following reasons: (1) in order to recognize slow MOVs, the same field must be observed three times on the same night with a temporal separation of at least 30 minutes, (2) for orbit computation purposes (i.e., reducing the effect of systematic observational errors), each field should be observed two or three times on a second closeby night, preferably subsequent but at maximum four days apart. For some objects, there are 2 or 3 target fields that should be observed because the ephemeris uncertainty is larger than the FOV of WFI. The above time sequence applies identically to the different fields for the same object. The target fields for a single TNO should be preferably all observed on the same night. In addition to the moving object OBs, each subfolder contain the OBs for calibration, see Special Calibration Information later in this file. OB SEQUENCES AND NAMING ======================= The names of the OBs reflect the sequence of execution, the general form is: MOV_##F#N#O#, where ## = target number, e.g. 01 for the first target F# = field number, e.g. F1 for the first target field N# = night number, e.g. N1 for the first night out of two O# = observation number, e.g. N1O1 for the first observations on the first night COOKBOOK INSTRUCTIONS ===================== First executed OB: ----------------- (1) Choose the target OB (i.e. the first OB that starts the sequence, E.G. MOV_##F1N1O1) based on observability ("Time intervals" and "Lunar illumination") and internal priority. (2) Execute the follow-up OBs (E.G. MOV_##F1N1O2, MOV_##F1N1O3) on the same night. (3) Execute the required calibration OBs (E.G. CAL_##F1N1 and Flat-##F1N1) on the same night. (4) Try to observe the follow-up OBs (MOV_##F1N2O1, MOV_##F1N2O2, MOV_##F1N2O3) on a closeby night. Subsequent OBs: --------------- (1) Check that no follow-up OBs are pending from the same night. (2) Check that no follow-up OBs are pending from the previous three nights. (3) Proceed as for the first executed OB above, from (1) onwards. EPHEMERIDES =========== A nightly ephemeris for each of the target fields is provided considering the observability period of the field. Because of the slow coordinate motion, RA&Dec are given only once per night at 04 UT, and the same coordinate values can be used through the night in question. Before starting the OB the SM observer must update the RA&Dec by selecting the values for the date from the corresponding ephemerides file. The ephemerides file that should be used for each OB are indicated also in the "Comments" field of the OB. Approved Waiver Request Summary ------------------------------- NA Critical Observing Condition Constraints ---------------------------------------- Clear, seeing < 1.2 arcsec, AM < 2.5, Moon distance > 15 deg, Lunar illumination < 0.7 for object magnitudes R < 23 mag and < 0.4 for magnitudes R = ~23 - 24 mag. Time Critical Aspects --------------------- Observations of each OB should be executed within the specified "Time Interval", although most of the OBs can be executed any time during the Period 73. OB sequences should be executed in the following way: - each FIELD (E.G. MOV_##F1..) should be observed THREE TIMES on the same night, with minimum TIME SEPARATION of 30 MINUTES between each OB. E.G. the three OBs MOV_##F1N1O1, MOV_##F1N1O2, and MOV_##F1N1O3 on the same night 30 minutes in between. - each FIELD should be observed TWO or THREE TIMES on a second night as explained above, with maximum TIME SEPARATION of FOUR DAYS between the nights. E.G. the three OBs MOV_##F1N2O1, MOV_##F1N2O2, and MOV_##F1N2O3 on the subsequent night or 2-4 days later. NOTE: The absolute minimum requirement for a succesful OB sequence is that each target field (E.G. MOV_F1..) is observed twice on two nights (E.G. MOV_##F1N1O1, MOV_##F1N1O2 and MOV_##F1N2O1, MOV_##F1N2O2). Please do not start the OB sequence if it is unlikely that this requirement is fullfilled, since a single executed OB cannot be used for the scientific purpose. Special Calibration Information ------------------------------- Since we are using no filter, we need to make the basic calibrations with sky flat fields. In addition to the moving object OBs, each subfolder (i.e., OB sequence) thus contain the following calibrations: * one calibration OB PER FIELD PER NIGHT consisting of an acquisition image and a science image of a standard star field observed again with no filter. E.g., CAL_01F1N1, CAL_01F1N2, or if there are two target fields which could be observed on different nights, also: CAL_01F2N1, CAL_01F2N2. Target: Landolt field SA107 No R.A. Dec. V Standard stars: 107 457 15 38 46 -00 20 33 14.91 107 215 15 38 57 -00 43 24 16.05 107 213 15 38 57 -00 44 32 14.26 107 357 15 39 05 -00 39 29 14.42 107 599 15 39 09 -00 14 46 14.68 107 640 15 40 49 -00 17 06 15.05 * one CalBlock with three sky flat fields taken with no filter. The photometric calibration is performed to get a rough estimate of the magnitudes of the object even though the observations are made without a filter due to the faintness of the objects and the effort to minimize the exposure times. Please note that one calibration block (and only one) of both kinds should be executed each night when one or more moving object OBs are executed. In each MOV OB which can start an OB sequence (i.e., OBs of the form MOV_##F#N#O1), the corresponding calibration OBs that should be executed are refered to in "Calibration Requirements". ToO Information --------------- NA Pre-Imaging Requirements ------------------------ NA OB Information ============== List of Science OBs ------------------- FC name: For moving targets, finding charts are not required. Ephemeris names: Total Number: 17 073.C-0685A.001.eph 073.C-0685A.002.eph 073.C-0685A.003.eph 073.C-0685A.004.eph 073.C-0685A.005.eph 073.C-0685A.006.eph 073.C-0685A.007.eph 073.C-0685A.008.eph 073.C-0685A.009.eph 073.C-0685A.010.eph 073.C-0685A.013.eph 073.C-0685A.014.eph 073.C-0685A.015.eph 073.C-0685A.017.eph 073.C-0685A.018.eph 073.C-0685A.019.eph 073.C-0685A.020.eph OB names: Not listed here due to the large number. Naming convention MOV_##F#N#O# Total Number of Submitted Science OBs: 102 List of Calibration OBs with Associated Science OBs --------------------------------------------------- OB names: Naming convention CAL_##F#N# Total Number of Submitted Calibration OBs: 34 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.