README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.C-0128(A) Principal Investigator Name: Belen Lopez Marti Principal Investigator E-mail Address: Belen.Lopez-Marti@uv.es Principal Investigator Telephone Number: +34 93 4021128 Principal Investigator Postal Address: Departament d'Astronomia i Meteorologia Universitat de Barcelona Facultat de Fisica, planta 7 Marti i Franques 1 E-08028 Barcelona (Spain) Instrument: VIMOS OPC Priority Class: B OPC Approved Total Execution Time: 22h Estimated Total Execution Time (including overheads): 21h 49min README File Submission Date: 10th May 2004 Programme Description ===================== General Overview ---------------- This is the MOS run for the programme "The low-mass end of the mass function: Spectroscopy of brown dwarf candidates in Lupus and Corona Australis". We want to take images of 20 fields in Lupus and 8 fields in Corona Australis, which contain the candidates identified in a previous photometric survey. The pre-imaging observations were performed in run A of this programme. Approved Waiver Request Summary ------------------------------- A total of 4.5 hours of observation had been approved for the pre-imaging run (run A of this programme) by the OPC. However, during the preparation of the OBs it became clear that 3.5 hours were sufficient for the purposes of the run. The remaining hour has been added to the MOS run after request. Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Special Calibration Information ------------------------------- We need bias, flats, arcs and standards from the calibration plan. In addition, flats and arcs should be taken during the night, as specified in the OBs. ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: The pre-imaging observations were performed in run 073.c-0128(A). OB Information ============== Four ADP files are included with each OB to build the corresponding masks. List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Lup-51 Lup-52 Lup-53 Lup-54 Lup-61 Lup-62 Lup-62b Lup-63 Lup-64 Lup-71 Lup-72 Lup-73 Lup-73b Lup-74 Lup-81 Lup-82 Lup-83 Lup-84 Lup-91 Lup-92 Lup-93 Lup-94 CrA-21 CrA-22 CrA-23 CrA-24 CrA-41 CrA-42 CrA-42b CrA-43 CrA-43b CrA-44 CrA-44b Total Number of Submitted Science OBs: 33 For every MOS OB there are 4 finding charts, corresponding to the 4 quadrants of the VIMOS detector. The quadrant is indicated as Q in the corresponding chart. Reference stars are indicated with squares, and science targets with lines (----) or double arrows (<-->). List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.