README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.B-0745(A) Principal Investigator Name: Rainer Schödel Principal Investigator E-mail Address: rainer@ph1.uni-koeln.de Principal Investigator Telephone Number: +49 (0)221 470 7788 Principal Investigator Postal Address: Universität zu Köln I.Physikalisches Institut Zülpicher Str.77 50937 Köln Instrument: NACO OPC Priority Class: B OPC Approved Total Execution Time: 22h Estimated Total Execution Time (including overheads): 19 h 35 min README File Submission Date: 25 Feb 2004 Programme Description ===================== General Overview ---------------- Our programme uses a number of NACO intermediate-band filters across the K-band to circumvent the difficulties listed above. With the SED measured across the K-band, stars can be roughly classified. Most importantly, the prominent CO-absorption trough of late-type stars at long wavelengths can be readily identified with this method. Thus they can be distinguished from MS stars. Observations for this programme will consist of imaging of two GC stellar fields (central field and a field offset toward NE) with the NACO S27 camera and 9 different IB filters. For the offset field, we also need Ks and J-Band imaging. The OBs are ordered in such a way, that the rough SED will be measured first (i.e. first observations at short and high wavelength ends and in the middle of the K-band). Gaps will be filled by subsequent OBs. The central field around Sagittarius A* (field 1) has the higher priority. Observations of this field should be completed before imaging the offset field (field 2). Brightest Object in the field: ------------------------------ The brightest object in field 1 (star cluster around Sagittarius A* is the supergiant IRS 7 (~6" north of Sagittarius A*). It has a magnitude of K = 6.5 and is also used as reference star for the IR WFS. Imaging of that field has been carried out routinely many times. The brightness of IRS7 did never pose any serious problems for the camera or the data quality. Objects in Field 2 have a brightness of K >= 10. AO Setup: --------- NAOS tries to acquire a background flux before closing the loop. Since this is done by default with a (0,0) offset, the background acquisition will usually fail because the GC is a very crowded field. Even if it does not fail, it will result in a very poor correction. Therefore, usually the background has to be acquired MANUALLY. In case of the central field (Field 1 with reference source IRS 7), we found that the offset (+9",-8"; from the reference source IRS 7) works very well (You can see in finding chart 1 that this region is devoid of bright stars). The AO mode is usually 2-1 (set automatically by NAOS). In case of bad seeing, we found that mode 3-2 gives a good correction. As for field 2, we have no experience with it yet. Standard procedure might work. If it doesn't, I recommend choosing an appropriate field for the background measurements from finding chart 2 (e.g. ~7" north of the reference source should work well). Image centering: ---------------- We use generic offsets, imaging the star cluster at 4 positions on the detector. As for the centering of the field at the start of of each OB, this should be done interactively (NACO_img_acq_MoveToPixel acquisition template). The respective initial FOV is indicated by a solid rectangle on the finding charts, with the detector centre marked by a circle. The pointing should be to 1-2" accurate. In case the OB has to be aborted because the AO crashes or because of other reasons, execution should be restarted at the beginning of the OB. The target MUST then be recentered (initial setting) in order to ensure accurate offsets. Telescope Offsets/Sky measurement: ---------------------------------- Please inform the TIO that a large telescope offset will be required for the sky measurements and guiding could be lost in case an inappropriate guiding star is selected. The sky offset is 713" W and 400" N. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Seeing: should be <= 0.8". However, more important than good seeing is good AO correction. Our experience is that seeing ~1" with long coherence times can provide excellent results as well. Transparency: Thin cirrus cover is ok. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Science OBs sorted according to user priority (first column; note: the p2pp GUI only allowed to set user priorities from 1 to 10): 1 gc_field1_ib227.obx 2 gc_field1_ib236.obx 3 gc_field1_ib230.obx 4 gc_field1_ib233.obx 5 gc_field1_ib224.obx 6 gc_field1_ib200.obx 7 gc_field1_ib206.obx 8 gc_field1_ib212.obx 9 gc_field1_ib218.obx 10 gc_field2_K.obx 11 gc_field2_J.obx 12 gc_field2_ib227.obx 13 gc_field2_ib236.obx 14 gc_field2_ib230.obx 15 gc_field2_ib233.obx 16 gc_field2_ib224.obx 17 gc_field2_ib200.obx 18 gc_field2_ib206.obx 19 gc_field2_ib212.obx 20 gc_field2_ib218.obx Total Number of Submitted Science OBs: 20 IMPORTANT: Field 1 has a higher priority than field 2 and should be observed first. Please execute OBs in same order as in the lists above. This will minimise damage in case part of the programme cannot be executed. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.