README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.B-0613(A) Principal Investigator Name: Victor P. Debattista Principal Investigator E-mail Address: debattis@phys.ethz.ch Principal Investigator Telephone Number: +41-01-633-2824 Principal Investigator Postal Address: Institut fuer Astronomie / ETH Hoenggerberg / HPF G4.2 / CH-8093 / Zuerich / Switzerland Instrument: ISAAC OPC Priority Class: C OPC Approved Total Execution Time: 10.0 Estimated Total Execution Time (including overheads): 9.9 README File Submission Date: 20 February 2004 Programme Description ===================== General Overview ---------------- This is a long-slit spectroscopy programme aimed to measure the bar pattern speed of the SBc galaxy NGC 4123. It completes ESO Programme 071.B-0091(A). We plan to take: 1) 2x35min SWS1-MR spectra along the galaxy major axis with the galaxy nucleus centered in the slit; 2) 4X30min SWS1-MR spectra with the slit parallel to the galaxy major axis with the slit center offset by 15 arcsec EASTWARD the nucleus; 3) 5X30min SWS1-MR spectra with the slit parallel to the galaxy major axis with the slit center offset by 15 arcsec WESTWARD the nucleus; 4) SWS1-MR spectra of 1 bright star to be used as kinematical template. The off-nucleus spectra with the slit parallel to the galaxy major axis have to be obtained by pointing to the galaxy NUCLEUS and then applying a BLIND OFFSET as specified in the relevant OB's. The acquisition Ks-band images will be used in data analysis. Therefore please DO NOT SKIP Ks-band acquisition images when taking the second spectrum in the same position. The 2MASS Survey does not list any object of the target field (12arcmin x 12arcmin). We assume that all the field stars have K>12 mag. The central surface brightness of NGC4123 is K=16 mag/arcsec^2. Kinematical template star is: name alpha(2000.0) delta(2000.0) J H K type --------- ----------- ------------ ----- ----- ----- ----- HD 129026 14:40:48.400 -17:58:32.700 7.74 7.20 7.05 K1III Approved Waiver Request Summary ------------------------------- None. Critical Observing Condition Constraints ---------------------------------------- The ZERO_NGC4321_MajAx OB has to be executed under photometric conditions. Time Critical Aspects --------------------- None. Special Calibration Information ------------------------------- Standard calibration are needed for spectroscopy (darks, flats, star traces, telluric standard stars, arcs) and acquisition Ks-band images (darks, twilight flat fields, zeropoints, illumination corrections). We asked fot nighttime arc exposures to ensure for an accurate wavelength calibration. This is necessary for measuring stellar kinematics. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 12 CAL_HD129026 K=7.05 NGC4123_MajAx K>12 NGC4123_OffAx15E_1 K>12 NGC4123_OffAx15E_2 K>12 NGC4123_OffAx15E_3 K>12 NGC4123_OffAx15E_4 K>12 NGC4123_OffAx15W_1 K>12 NGC4123_OffAx15W_2 K>12 NGC4123_OffAx15W_3 K>12 NGC4123_OffAx15W_4 K>12 NGC4123_OffAx15W_5 K>12 ZERO_NGC4123_MajAx K>12 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 NONE. OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.