README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID:073.B-0398(A) Principal Investigator Name: M. Calvani Principal Investigator E-mail Address: calvani@pd.astro.it Principal Investigator Telephone Number: +39-049-8293431 Principal Investigator Postal Address: INAF, Osservatorio Astronomico di Padova, Vicolo dell' Osservatorio 5, I-35122 Padova, Italia Instrument: ISAAC OPC Priority Class: C OPC Approved Total Execution Time: 38h Estimated Total Execution Time (including overheads): 38h04m README File Submission Date: Programme Description ===================== The programs consists of SW-LR observations with ISAAC in the SZ,J, and H bands of quasars. All sources have been assigned the priority 1, and we do not have any special preference for the order in which OBs are executed. However, for two objects, two OBs have been defined, as observations in two bands are needed to cover Hbeta and one of the nearby FeII multiplets. For such objects ** both OBs should be executed if possible **, albeit not necessarily one immediately after the other. A user comment has been added in the OBs, and the less important OB has been assigned priority 2. General Overview ---------------- This program is aimed at observing Hbeta and the FeII blend at 4570 or at 5130 of intermediate redshift quasars from the ESO-Hamburg quasar survey. Spectra are to be collected in LR mode with slit width 0.6 arcsec. Approved Waiver Request Summary ------------------------------- 073.B-0398A.01.WAV We asked that the condition on OB length to be less tham 1h05m be removed for our project. Observations of faint quasars require minimum exposures ~60m-90m to reach minimum acceptable S/N with optimal settings. The alternative to split the OB into two separate OBs will decrease significantly the observing efficiency. At any rate, longest execution times for our projects are within ~2h, with most execution times ~ 1h00m. Dear Drs. Calvani and Marziani, your waiver request to execute OBs of more than 1h has been granted, with the usual restriction that if the conditions degrade in violation of the constraints after the first hour, the OB will not be repeated. Best regards, Markus Wittkowski Critical Observing Condition Constraints ---------------------------------------- None. Time Critical Aspects --------------------- None. Special Calibration Information ------------------------------- No special calibration is required, as wavelength calibration will be achieved through OH skylines, and spectrophotometric calibration through the standard calibration plan is deemed of sufficient accuracy. ToO Information --------------- No ToO Pre-Imaging Requirements ------------------------ Source of preimaging: None. OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Id | OB Name - --------------------------- 154125 HE 0010-4050 154127 HE 0035-2853 154129 HE 0043-2300 154131 HE 0058-3231 154133 HE 0105-3006 154135 HE 0109-3518 154137 HE 0119-3325 154139 HE 0142-4619 154141 HE 0142-4619-0 154142 HE 0203-4627 154144 HE 0203-4627-0 154145 HE 0205-3756 154147 HE 0224-3826 154149 HE 0229-5603 154151 HE 0239-4809 154153 HE 0248-3628 154155 HE 0251-5550 154157 HE 0349-5249 154159 HE 0359-3959 154161 HE 0435-4312 154163 HE 0435-5304 154165 HE 0436-3709 154167 HE 0439-5254 154169 HE 0502-2727 154171 HE 0507-3226 154173 HE 0512-3329 154175 HE 0517-3649 154177 HE 1505+0212 154179 HE 2147-3212 154181 HE 2156-4020 154123 HE 2335-3029 Total Number of Submitted Science OBs: 31 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.