README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.A-9007(A) Principal Investigator Name: Klaus Meisenheimer Principal Investigator E-mail Address: meise@mpia.de Principal Investigator Telephone Number: +49 6221 528 206 Principal Investigator Postal Address: Max-Planck-Institut fuer Astronomie, Koenigstuhl 17, D-69117 Heidelberg Instrument: WFI OPC Priority Class: A OPC Approved Total Execution Time: 40 hours dark, 10 hours grey Estimated Total Execution Time (including overheads): 49:35 hours README File Submission Date: 28/Jun/2004 Programme Description ===================== This is WFI imaging in the standard R and V filters plus in the non-standard filters: B_99 and U_38, as well as 11 additional medium band filters. Total integration time per filter substantially exceed one hour. Therefore, it had to be split into a set of OBs for each filter. In order to avoid excessive overheads some of these OBs require integration times slightly longer than 1 hour. None of these OBs should be repeated if it has to be stopped after 1 hour. Before observing the highly resolved R-band image in The A226 field (seeing < 0.8 arcsec) the instrument focus should be checked. IMPORTANT NOTE: We use the standard auto-dither pattern for the first OB of each filter (labeled by the letter a). Further integrations contained in additional OBs (indicated by b,c, ...) extend the dither pattern to up to 10 positions. Unfortunately, p2pp does not allow to order the OBs. Thus often, the FIRST OB (e.g. A226_R-1a) has a higher OB ID than the second one (A226_R-1b). The observations should be carried out along the sequence a,b,c... ! Approved Waiver Request Summary ------------------------------- No waiver request Critical Observing Condition Constraints ---------------------------------------- The R band OBs should be carried out under the BEST seeing conditions, that is telecope seeing < 0.8 arcsec (as measured on a 300 sec R band exposure). Time Critical Aspects --------------------- None Special Calibration Information ------------------------------- Additional calibration (only sky_flats during twilight) requested for B_99, U_38, and 11 medium band filters. ToO Information --------------- No ToO Pre-Imaging Requirements ------------------------ None OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 46 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 26 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] Y [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.