README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.A-0844(A) Principal Investigator Name: B. Garilli Principal Investigator E-mail Address: bianca@mi.iasf.cnr.it Principal Investigator Telephone Number: +39-02-23699313 Principal Investigator Postal Address: IASF-MI / via Bassini 15 / 20133 Milano / Italy Instrument: VIMOS-IFU OPC Priority Class: A OPC Approved Total Execution Time: 32h Estimated Total Execution Time (including overheads): 32h README File Submission Date: 24/02/2004 Programme Description ===================== General Overview ---------------- Our proposal aimed to gather information on the kinematical signatures of morphological transformations of galaxies in cluster. We proposed to observe objects of different morphological types in 2 clusters at z~0.5 in a different dynamical stage. Central objects will be observed with VIMOS-IFU and peripherical objects with FLAMES-IFU. Using VIMOS we want to make 2 pointings per cluster (ie 4 pointings in total). Approved Waiver Request Summary ------------------------------- WaiverID: 073.A-0844A.01 This waiver request concerns the VIMOS part only. Based on the ESO ETC for VIMOS we estimated that ~6h30 is need to get a S/N ration per pixel about 5 for a galaxie (S0) at R~22 and 10 at R~20.5. Adding calibrations and oveheads for ~20%, total estimated time requested, and allocated, was 32h. Using the p2pp program, and following the outfits, we should have to divide our total time into 32 OBs of 1h. Each OBs has an overhead of more than 20minutes, in VIMOS IFU configuration, and this reduce our integration time on the objects to 4h55min per pointing ie ~40% of the time is spent on the overheads. This will reduce the S/N reach to ~4 for a galaxie (S0) at R~22. This means that although the proposal has been accepted for the total observing time requested, we cannot carry out our program. In a case like this, where total observing time per pointing is more than 6 hours on source, dividing OBs into a maximum of 1 hour each, with 40% overhead each time for calibrations, instrument configuration, pointing etc, is extremely unefficient. We asked a waiver to submit OBs for a total of 2 hours time each, thus reducing overheads to ~20% on the proposal as a whole. This request was submitted on 11 February 2004 and approved on 12 February 2004. Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 16 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.