3 32 README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 073.A-0764(A) Principal Investigator Name: Ivo Labbe Principal Investigator E-mail Address: ivo@strw.leidenuniv.nl Principal Investigator Telephone Number: +31-71-5275805 Principal Investigator Postal Address: Leiden Observatory / P.O. Box 9513 / NL-2300 RA / Leiden / The Netherlands Instrument: ISAAC OPC Priority Class: A OPC Approved Total Execution Time: 30.0 Estimated Total Execution Time (including overheads): 30.0 README File Submission Date: Fri Mar 26 2004 Programme Description ===================== General Overview ---------------- This is a ultradeep imaging programme on a single pointing consisting of one sequence of 28 independent Observation Blocks. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- We want to go ultradeep, which requires the best possible seeing, hence we request very good seeing of better than 0.6 arcsec on this single field. We hope to get an average seeing better than 0.5 arcseconds in K. Some cirrus is not a problem. Four of the 28 OBs are executed under photometric conditions as indicated by their associated constraint set (the postfix of the OBnames is "-zero"). This is for the purpose of accurate flux zeropoint determinations of the deep field. About 15% of total execution time is allocated to these photometric observations. Precise centering of the OBs is important for the best quality reduction. We request that one of the brightest stars in the field (magnitude Ks = 16, located at ra=03:32:42.44 dec=-27:47:59.34) is centered on ISAAC pixel (x=878 y=463). This reference star is indicated in the finding chart. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) All OBs on a single field: brightest star K=14.6 udf-acs-isaac-K-01-zero udf-acs-isaac-K-02 udf-acs-isaac-K-03 udf-acs-isaac-K-04 udf-acs-isaac-K-05 udf-acs-isaac-K-06 udf-acs-isaac-K-07 udf-acs-isaac-K-08-zero udf-acs-isaac-K-09 udf-acs-isaac-K-10 udf-acs-isaac-K-11 udf-acs-isaac-K-12 udf-acs-isaac-K-13 udf-acs-isaac-K-14 udf-acs-isaac-K-15-zero udf-acs-isaac-K-16 udf-acs-isaac-K-17 udf-acs-isaac-K-18 udf-acs-isaac-K-19 udf-acs-isaac-K-20 udf-acs-isaac-K-21 udf-acs-isaac-K-22-zero udf-acs-isaac-K-23 udf-acs-isaac-K-24 udf-acs-isaac-K-25 udf-acs-isaac-K-26 udf-acs-isaac-K-27 udf-acs-isaac-K-28 Total Number of Submitted Science OBs: 28 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.