README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID:073.A-0564(C) Principal Investigator Name: Malcolm Bremer Principal Investigator E-mail Address:m.bremer@bristol.ac.uk Principal Investigator Telephone Number:+44 117 928 8764 Principal Investigator Postal Address:H.H. Wills Physics Laboratory, Univ. of Bristol, Tyndall Avenue, Bristol BS8 1TL, UK Instrument: FORS2 OPC Priority Class:A OPC Approved Total Execution Time:10 hrs Estimated Total Execution Time (including overheads): 9hs 55mins README File Submission Date: 25-03-04 Programme Description ===================== General Overview ---------------- 3 hrs R, 1 hr I, 3.5 hrs in Z on a deep field, to select candidate R and I dropouts ( z>5 galaxies) for subsequent FORS2 spectroscopy. Although this is "preimaging" this needs to be done as a stright imaging programme as we need to photometrically select our candidate objects. This is identical to what has happened in the past two years on neighboring fields. This year we are doing BDF 3 and 4, having previously completed BDF 1 and 2. Approved Waiver Request Summary ------------------------------- A single OB (Pre_image_Bremer_deep_3_I_1h) runs over the hour by 27 seconds. This is identical to last year & this caused no problems last year (we checked last year if we required a waiver & you said no). One OB each for R, I Z has been changed to "phot" from "clear" as requested by Monika during the review of the OBs. Critical Observing Condition Constraints ---------------------------------------- None, beyond the constraint set Time Critical Aspects --------------------- None, exept needs to be done fairly early in semester in order to set up the fields for the spectroscopy. in the subsequent dark period(s) Special Calibration Information ------------------------------- Standard photometric calibs ToO Information --------------- Pre-Imaging Requirements ------------------------ These OBs are classified as "preimaging", but need to be deep and photometrically calibratable, as they form the way we select our targets, hence they are really "classical£ deep images. As in previous years we have followed your advice to classify these as "pre_images" in the OBs so everyone is aware they must be obtained before we can do our spectroscopy. Source of preimaging: These images OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Pre_image_Bremer_deep_4_I_1h Pre_image_Bremer_deep_4_R_1h_a Pre_image_Bremer_deep_4_R_1h_b Pre_image_Bremer_deep_4_R_1h_c Pre_image_Bremer_deep_4_R_1h_d Pre_image_Bremer_deep_4_Z_1h_a Pre_image_Bremer_deep_4_Z_1h_b Pre_image_Bremer_deep_4_Z_1h_c Pre_image_Bremer_deep_4_Z_1h_d Pre_image_Bremer_deep_4_Z_1h_e Total Number of Submitted Science OBs: 10 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs:0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA]Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA]Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA]NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA]NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.