README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: 072.D-0433(A) Principal Investigator Name: Petri Vaisanen Principal Investigator E-mail Address: pvaisane@eso.org Principal Investigator Telephone Number: +56-2-463-3063 Principal Investigator Postal Address: ESO, Alonso de Cordova 3107, Vitacura, CHILE Instrument: NACO/VLT OPC Priority Class: A OPC Approved Total Execution Time: 15 h Estimated Total Execution Time (including overheads): 15 h README File Submission Date: 28/08/2003 Programme Description ===================== General Overview ---------------- Observations of 13 Ultraluminous Infrared Galaxies (ULIRGs) will be obtained with NACO in Ks band to detect several highly obscured supernovae (SNe) within the nuclear regions (~0.5-2 arcsec diameter) of the target ULIRGs. This programme consists of imaging the targets twice over two Periods to allow SN detection by comparison of the images. Approximately half of the OBs use the ULIRG nucleus as the AO reference with the IR WFS. The others use a nearby star with the VIS WFS. All the reference objects are relatively faint (V~13-15, K~13). In some cases the ULIRG has more than one distinct nuclei: PLEASE CENTER THE FIELD TO THE MIDDLE OF THESE after acquisition. We have included higher-resolution FCs for most of such cases, and the nucleus to be used as the reference is indicated. If no high-resolution FC is available, please use the brightest nucleus to guide the AO in such cases. Autojitter imaging templates are used throughout. There are no objects brighter than K~10 mag in any of the fields. Approved Waiver Request Summary ------------------------------- WaiverID: 072.D-0433A.01. Waiver to exceed the 1h OB limit for 5 OBs was approved under the condition that, if observing conditions degrade below specified constraints after 1h, observations will not be repeated. The concerned OBs have execution time of ~1h 15min. Critical Observing Condition Constraints ---------------------------------------- Seeing < 0.6". It is very important that our constraints for both the seeing (strehl) and airmass are met. The AO reference sources are generally faint (V~14, K~13) but the best possible AO performance is critical here for the science. Sky transparency is of less importance. The INSTRUMENTAL COUNTS SHOULD ALWAYS BE BELOW THE LINEARITY LIMIT FOR ALL THE PIXELS IN THE CENTERS OF THE ULIRG NUCLEI. This is essential for our convolution and image subtraction methods to work properly, to detect SNe in the nuclear (central 1" radius) regions. Please, use short enough DITs to allow also for improvement of SR during the OBs. Improvement of effective seeing from 0.6" to 0.4" is expected to change SR by ~50% and ~100% for targets with the ULIRG nucleus and nearby star as the AO reference, respectively. Time Critical Aspects --------------------- The same targets will be observed during the next Period (P73). Our SN detection rate increases with the length of the time interval between the two observations. It is thus preferred that targets are observed as soon as it is feasible during this Period. We note that IRAS19297, IRAS19458 and IRAS20046 are setting very quickly in the beginning of P72 below the airmass required for succesful AO correction. If it becomes necessary, these OBs can well be carried over to P73 without affecting the science, since there is ample time for two observations of these sources during P73. IRAS 05189-2524 will be observed twice during Period 72. The 2nd observation should be separated from the first one by more than 2 months. Please see the time windows of the corresponding OBs. An immediate ftp access to the 2nd observation data is required in order to allow rapid SN detection from the data. This is necessary for the follow-up observations of the detected SNe when they are still bright enough at the near-IR wavelenghths. Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- I00199-7426 072.D-0433A.001.ps I00199-7426-II 072.D-0433A.001.ps I05189-2524-I 072.D-0433A.002.ps I05189-2524-II 072.D-0433A.002.ps I10565+2448 072.D-0433A.004.ps I14348-1447 072.D-0433A.005.ps & 072.D-0433A.006.ps I14378-3651 072.D-0433A.007.ps I17208-0014 072.D-0433A.008.ps I19297-0406 072.D-0433A.009.ps I19458+0944 072.D-0433A.010.ps I20046-0623 072.D-0433A.011.ps I20414-1651 072.D-0433A.012.ps I20551-4250 072.D-0433A.013.ps I23128-5919 072.D-0433A.014.ps & 072.D-0433A.015.ps Total Number of Submitted Science OBs: 14 Total Number of Submitted Finding Charts: 15 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.