README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: : 072.C-0689(D) Principal Investigator Name : Mark McCaughrean Principal Investigator E-mail Address : mjm@aip.de Principal Investigator Telephone Number : +49 (0)331 749 9525 Principal Investigator Postal Address : Astrophysikalisches Institut Potsdam An der Sternwarte 16 14482 Potsdam, Germany Instrument: : FORS2 OPC Priority Class: : A OPC Approved Total Execution Time : 2.0 hours Estimated Total Execution Time (including overheads) : 2.0 hours README File Submission Date: 26th September 2003 Programme Description ===================== General Overview ---------------- This is one part of a complex program of ISAAC, FORS2, and NACO imaging and spectroscopy observations of Eps Indi Ba,Bb, the nearest known binary brown dwarf / T dwarf system. The binary has a separation of 0.732 arcsec at a position angle 137 degrees E of N. The system also has a very high proper motion of 4.7 arcsec/yr. This part of the program covers FORS2 imaging photometry in the VRIz bands. There are also corresponding observations of a standard star (PG2213-006) which we need to make sure we have a z-band calibration: these standard star OBs should be observed immediately preceding or following the corresponding Eps Indi B OBs. We are relying on the calibration plan to provide full zeropoints and extinction coefficients. IMPORTANT: If possible, all blocks should be observed within a single night: T dwarfs are variable on timescales of days. IMPORTANT: The observations of PG2213-006 are intended as an extra calibration above and beyond those provided by the standard service mode calibration plan. It is important that efforts be made to observe PG2213-006 and/or the standard chosen for the calibration plan as close as possible in time and airmass to Eps Indi B. For Eps Indi B, there is one OB covering all 3 of R, I, and z, with integration times of 60, 20, and 10 seconds, respectively, with 5 dithered positions per filter. For V, the onchip integration time is 500 seconds with 5 dithered positions again. For the standard, there is one OB covering the V band, with 5 seconds onchip and 5 positions: this block should be observed immediately preceding or following the Eps Indi B V block. The other OB is for R, I, and z, with 5 seconds onchip and 5 positions per filter: this block should be observed immediately preceding or following the Eps Indi B RIz block. There are two associated finding charts, both for Eps Indi B, and both taken from the same UK Schmidt I band plate: one (001.ps) is 4.2x4.2 arcmin in size; the other (002.ps) is 6.8x6.8 arcmin in size. IMPORTANT: As Eps Indi Ba,Bb moves at 4.7 arcsec per year, it has moved quite some distance since the 1997.77 epoch of the plate: its location in 1997.77 is marked with an arrow, while the cross at the centre of the image marks where the source is to be found at epoch 2003.8. Approved Waiver Request Summary ------------------------------- None. Critical Observing Condition Constraints ---------------------------------------- IMPORTANT: The original proposal requested 1 arcsec seeing, before it was known that Eps Indi B is a binary. We have thus requested and been granted permission to upgrade our observations to have a constraint of 0.6 arcsec seeing or better, in order to be able to separate the two sources. The better the seeing we can get, the better the results. Time Critical Aspects --------------------- None Special Calibration Information ------------------------------- We have provided OBs for an auxiliary standard star, which should be taken immediately preceding or following the corresponding Eps Indi B observations. ToO Information --------------- No ToO observations are requested. Pre-Imaging Information ----------------------- No preimaging is required for this programme. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 2 Total Number of Submitted Finding Charts: 2 epsindib_forsphot_v = 072.C-0689D.001.ps, 072.C-0689D.002.ps epsindib_forsphot_RIz = 072.C-0689D.001.ps, 072.C-0689D.002.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 2 pg2213-006_forsphot_v = associated with epsindib_forsphot_v pg2213-006_forsphot_RIz = associated with epsindib_forsphot_RIz Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Y Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] Y [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.