README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: Artie Hatzes Principal Investigator Name: Artie Hatzes Principal Investigator E-mail Address: artie@tls-tautenburg.de Principal Investigator Telephone Number: +49-36427-863-51 Principal Investigator Postal Address: Prof. Dr. Artie Hatzes Thueringer Landessternwarte Tautenburg Sternwarte 5 D-07778 Tautenburg Germany Instrument: UVES OPC Priority Class: B OPC Approved Total Execution Time: 7.5 Estimated Total Execution Time (including overheads): 7.5 README File Submission Date: 18 Aug 2003 Programme Description ===================== General Overview ---------------- These are spectroscopic observations with UVES using the UVES_red_obs_exp 600 standard setting and the iodine absorption cell. The cell is used for precise radial velocity measurements and is placed in the the light path during an observation. We are making observations of the same stars for two epochs. Thus the target list for runs A and B are the same. We only need a few template spectra (star without iodine) and these are divided equally between run A and B. The naming convention for the OBs are "objectname_type_n" where objectname is the object, type is either "iodine" or "template" and n is the number of observation for that object (over the runs A and B). "template" refers to an observation without the iodine cell "iodine" refers to an observation with the iodine cell in place. ******* IMPORTANT *************************************************** As part of the reduction procedure we need to deconvolve the instrumental profile from the template spectrum (spectrum of star without iodine). To do that requires an observation of a hot star (HR 948) taken through the cell (the standard iodine spectrum through the flat is insufficient for this). Thus, when you take a template spectrum you should also observe the hot star HR 948 once through the cell and once without (through the cell has the highest priority). **** If you do not take a template spectrum on a given night do not take a spectrum of the calibration hot star (HR 948), I repeat do not waste an OB observing on HR 948. That observation would be useless and an OB will be wasted!! **** Please note, that if several template spectra of different stars are taken on the same night, then only one series of HR 948 (through cell and without cell) is needed. If you can, try to take several template observations in the same night as this is more efficient and requires less OBs. Note that the first time a star is observed it makes sense to take a sequence with the cell and then one without (this will save acquisition time). Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- This project can be carried out under reasonably poor seeing conditions. Time Critical Aspects --------------------- The same targets are observed for run A and B and it is advantageous that you maximize the time between the dates of runs A and B. These observations (B) should be made near the end of the semester, preferably in late Jan or Feb. (The Hyades are not well accessible if you go too late in Feb, Mar. but if you can still acquire the objects this late in the season (i.e. Mar), then take the observations then. Special Calibration Information ------------------------------- Just standard calibration is needed (ThAr, Flat, Bias, Iodine spectrum (i.e. flat lamp taken through the iodine cell). *** It is important that along with the other calibrations that an iodine spectrum is taken using the flat lamp. *** ToO Information --------------- Pre-Imaging Requirements ------------------------ OB re using image slicer #3. Slit-viewer should be used to put the object into the image slicer. This is a crowded field so the finding charts will definitely be needed. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 22 Total Number of Submitted Finding Charts: 16 Even though I have submitted finding charts they should not be needed since all of these stars are bright. The object should be the brightest star in the field. OB: Finding Chart HR948_template_calb_3-5 None, 6 mag star! HR948_iodine_calb_3-5 None, 6 mag star! vA637_iodine_2 072.C-0264B.001.ps vB42_iodine_2 072.C-0264B.002.ps HD283869_iodine_2 072.C-0264B.003.ps HD283869_template 072.C-0264B.003.ps vA529_iodine_2 072.C-0264B.004.ps vB99_iodine_2 072.C-0264B.005.ps vb87_iodine_2 072.C-0264B.006.ps vB76_iodine_2 072.C-0264B.007.ps vB25_iodine_2 072.C-0264B.008.ps vb10_iodine_2 072.C-0264B.009.ps HD286789_iodine_2 072.C-0264B.010.ps HD286789_template_2 072.C-0264B.010.ps HD286589_iodine_2 072.C-0264B.011.ps HD285837_iodine_2 072.C-0264B.012.ps HD284930_iodine_2 072.C-0264B.013.ps HD284552_iodine_2 072.C-0264B.014.ps BD+08642_iodine_2 072.C-0264B.015.ps BD+04810_iodine_2 072.C-0264B.016.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.