README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: 072.B-0395(A) Principal Investigator Name: Romano Corradi Principal Investigator E-mail Address: rcorradi@ing.iac.es Principal Investigator Telephone Number: +34 922 425 461 / +34 922 425 441 Principal Investigator Postal Address: Isaac Newton Group of Telescopes / Apartado de correos 321 / E-38700 Santa Cruz de la Palma / Tenerife/ Spain Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 0.5 Estimated Total Execution Time (including overheads): 0.5 (2x 14mn59s) README File Submission Date: 19 August 2003 Programme Description ===================== Simple Pre-Imaging program with 2 galaxies observed with two filters (Halpha and R Special). General Overview ---------------- Split Ha exposures to minimize/avoid the saturation problem: there are several bright stars 12 < Mv < 14 in the fields. PLEASE CHECK: the short Halpha exposure should NOT saturated at all for the 5 reference stars. For Sextans_B the reference stars are fainter than Mv=14, should not be a problem. For Sextans_A the reference stars are brighter. Note: According to the ETC, a Mv=12 star (T=20s, seeing 0.8", Moon=10) will have a central pixel value of 5 Millions e- (~50x the saturation level). Is this a problem for the CCD (how many pixels are affected by bleeding) ? NOT observable in Sep-Oct-Nov(beginning) First UT4 service suitable period to be observed (Nov 20-22th, or Nov 30th) Approved Waiver Request Summary ------------------------------- We have request that the second part (B) will be sent later after Pre Imaging has been completed. Critical Observing Condition Constraints ---------------------------------------- Should not observe close to the Moon (ie close to FULL moon ==> Moon dist > 30). Photometric conditions are not required. Time Critical Aspects --------------------- No observation during full Moon Special Calibration Information ------------------------------- NO ToO Information --------------- NO Pre-Imaging Requirements ------------------------ This is the Pre-Imaging request. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 2 Total Number of Submitted Finding Charts: 2 Pre Imaging Sextans_A = 072.B-0395A.001.ps Pre Imaging Sextans_B = 072.B-0395A.002.ps FC are with the Master CCD down (PA=205 --> Rot=155) to get at minimum the 5 reference stars. Potential slits (8" long) are also drawn. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.