README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: 072.B-0248A Principal Investigator Name: Jens Zuther Principal Investigator E-mail Address: zuther@ph1.uni-koeln.de Principal Investigator Telephone Number: 00492214703495 Principal Investigator Postal Address: 1.Physikalisches Institut / Universitaet zu Koeln / Zuelpicher Str. 77 / 50937 Koeln / Germany Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 23.0h Estimated Total Execution Time (including overheads):22.5h README File Submission Date: 20.08.2003 Programme Description ===================== General Overview ---------------- This is a spectroscopy program in H and K in low resolution mode with the 1 arcsec slit at two slit positions on the target 3C48. Acquisition is done on the pointlike 3C48 QSO itself. Approved Waiver Request Summary ------------------------------- No request. Critical Observing Condition Constraints ---------------------------------------- No critical constraints. Time Critical Aspects --------------------- No time critical aspects. Special Calibration Information ------------------------------- No special calibration information. We rely on the standard calibration. ToO Information --------------- This is not a ToO program. Pre-Imaging Requirements ------------------------ No requirements. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 24 Total Number of Submitted Finding Charts: 4 Spectroscopy: slit 1, priority 1 (highest) This slit should also contain a BAL QSO at RA= 01 37 40.67, DEC= +33 08 56.8 (J2000.0) with H-mag ~ 19.1 and Ks-mag ~ 18.5 H-band: 3C48_ISAAC_SWSpec_Slit1_H-0 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_H-1 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_H-2 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_H-3 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_H-4 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_H-5 = 072.B-0248A.001.ps, 072.B-0248A.002.ps K-band: 3C48_ISAAC_SWSpec_Slit1_K-0 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_K-1 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_K-2 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_K-3 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_K-4 = 072.B-0248A.001.ps, 072.B-0248A.002.ps 3C48_ISAAC_SWSpec_Slit1_K-5 = 072.B-0248A.001.ps, 072.B-0248A.002.ps slit 2, priority 2 H-band: 3C48_ISAAC_SWSpec_Slit2_H-0 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_H-1 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_H-2 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_H-3 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_H-4 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_H-5 = 072.B-0248A.001.ps, 072.B-0248A.003.ps K-band: 3C48_ISAAC_SWSpec_Slit2_K-0 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_K-1 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_K-2 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_K-3 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_K-4 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 3C48_ISAAC_SWSpec_Slit2_K-5 = 072.B-0248A.001.ps, 072.B-0248A.003.ps 072.B-0248A.001.ps: 2Mass image centered on 3C48 showing the two slit positions. 072.B-0248A.002.ps: ISAAC H-band image centered on 3C48 with slit 1 indicated. 072.B-0248A.003.ps: ISAAC H-band image centered on 3C48 with slit 2 indicated. Priority 1 is highest. Priority 2 is should be carried out when priority 1 is completed. Acquisitions is carried out in filters H and K on 3C48 itself. Brightness of 3C48 in H=14.3 and Ks=13.4 List of Calibration OBs with Associated Science OBs --------------------------------------------------- No special calibration. We rely on the standard calibration. Total Number of Submitted Calibration OBs: 0 Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.