README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: 072.A-9003(B) Principal Investigator Name: Hermann-Josef Roeser Principal Investigator E-mail Address: roeser@mpia.de Principal Investigator Telephone Number: 0049 - 6221 - 528 209 Principal Investigator Postal Address: Koenigstuhl 17 D69117 Heidelberg Germany Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 15h dark, 7h grey Estimated Total Execution Time (including overheads): 21h 33min README File Submission Date: 13-Nov-03 Programme Description ===================== General Overview ---------------- This is a survey project to image an area of 3 square degrees. For each pointing we need a short image (which does not saturate brighter stars) and a dithered sequence of 7 images of 500 sec each. This is repeated for B and R. To obtain the required total integration time these sequences may have to be executed several times. We therefore provide an OB which is used for field aquisition (HIROCS_Mii_B/R.obx for a single sequence or HIROCS_Mii_B_a/R_a.obx if more than one sequence is needed). In case of several such sequences we also provide HIROCS_Mii_B_b/R_b.obx or even HIROCS_Mii_B_c/R_c.obx. For the b and c versions the object coordinates are the same as for version a. After acquisition of b or c OB therefore please offset by 10" to the north in case of b, and by 10" to the north and 10" to the west in case of c. Therefore the finding charts with alignment stars are provided for version a only. To ensure accurate pointing we use move-to-gap and supply pixel coordinates on the real-time-display for a selected moderately bright star close to the array center. The center is assumed to be at pixel coordinates [4289, 4126]. The star is marked on the finding chart by an orange circle and the corresponding pixel coordinates are given at the bottom of the finding chart. Approved Waiver Request Summary ------------------------------- OB execution time of 1:22 confirmed by A. Kniazev. Critical Observing Condition Constraints ---------------------------------------- Seeing should be better than 1.5 arcsec. We do not need photometric conditions. Light cirrus is tolerable in dark time. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 17 Total Number of Submitted Finding Charts: 5 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 2 Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA]Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA]Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA]NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA]Y [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission. Dokument1 13.11.2003 / 16:12 2 / 3