README Template 72.1 (please do not delete the README Template Version line!) ESO Programme ID: 072.A-0100(A) Principal Investigator Name: Michael Murphy Principal Investigator E-mail Address: mim@ast.cam.ac.uk Principal Investigator Telephone Number: +44-1223-337505 Principal Investigator Postal Address: Institute of Astronomy / Madingley Road / Cambridge CB3 0HA / UK Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 6.0 Estimated Total Execution Time (including overheads): 6.0 README File Submission Date: 21 August 2003 Programme Description ===================== General Overview ---------------- This is a novel spectroscopic program to obtain a bright QSO spectrum through the iodine cell. Six exposures are required of the QSO, 3x40min with the iodine cell in place and 3x51min without the iodine cell ("clean" below). These are arranged in 4 OBs below. To correctly apply the iodine cell wavelength calibration to the clean QSO spectrum, several smooth stellar spectra must also be observed. Three separate OBs cover 3 different smooth stars with greatly varying brightness. All exposures must be taken with the same experimental setup and, if at all possible, all OBs should be executed on the same night (this will eliminate instrument setting changes between observations). As this may not be likely, execution of OB.4, OB.5, OB.6 and OB.7 on a second night of observations (preferably the night after the other OBs and at roughly the same hour angle) would be a useful alternative. Approved Waiver Request Summary ------------------------------- Phase 2 Waiver Request Contact: Ferdinando Patat 1) OBs longer than 1 hour: OB.2 and OB.7 below require more than 1 hour execution time. 2) Non-standard R580 iodine cell template: Usually the R600 setting is used for all iodine cell observations. This setting would place two crucial transitions on the bluest order of the upper red CCD (order 101) and so would risk severe degredation to the science quality of the data. Therefore, ALL OBs below (including the iodine cell observations) are to be carried out with the R580 setting. It was also agreed that the usual iodine cell "calibration plan" exposures would be provided in the R580 setting instead of R600 (i.e. 1xThAr + 5xFlat w/o I2-cell + 5xFlat WITH I2-cell in the R580 setting are to be provided). The undersized pupil-stop should also be used for these calibrations. Critical Observing Condition Constraints ---------------------------------------- The seeing should not be too small. A seeing of 0.8" is ideal for these 0.7"-slit observations. If seeing is < 0.6", guiding errors could become important. Time Critical Aspects --------------------- The OBs below should be executed in the order they appear below. This should be facilitated by the object RAs involved. Again, as a preference, all OBs should be executed on the same night if possible or the groups (OB.1, OB.2, OB.3) and (OB.4, OB.5, OB.6, OB.7) could be executed on consecutive nights. Special Calibration Information ------------------------------- All exposures to be taken with the undersized pupil stop, including all calibrations in calibration plan (with R580 setting). OB.5 and OB.7 have an attached ThAr wavelength calibration. Just repeating the waiver request information above: the usual iodine cell "calibration plan" exposures should be provided in the R580 setting instead of R600 (i.e. 1xThAr + 5xFlat w/o I2-cell + 5xFlat WITH I2-cell in the R580 setting are to be provided). The undersized pupil-stop should also be used for these calibrations. ToO Information --------------- This is not a ToO program. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this program. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 7 Total Number of Submitted Finding Charts: 1 OB.1_EG21_1xIodine = Object brightest in field, no finding chart required. OB.2_QSO_2xIodine = 072.A-0100A.001.ps OB.3_HR1996_1xIodine = Object brightest in field, no finding chart required. OB.4_QSO_1xIodine = 072.A-0100A.001.ps OB.5_QSO_1xClean = 072.A-0100A.001.ps OB.6_HD49798_1xIodine = Object brightest in field, no finding chart required. OB.7_QSO_2xClean = 072.A-0100A.001.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 Phase 2 package Compliance Checks ================================= (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.