European
Southern Observatory
New Technology Telescope |
| General : | |||||
| Observations : | |||||
| Operations : |
![]()
| Procedure: | SOFI Mask/Slit Wheel - Failure |
| Author: | Leo Vanzi & V. Doublier |
| Release: | 1.0/ June 22, 2002 |
Check
Slit/Mask wheel status: if OFF then put StandBy, if ONLINE (spurious) then out
it OFF then StandBy
- open ICS control panel (if not already up)
1- Use the handset tool
- on the ICS control panel: Tools -> handset tool - select speed ~ 500
- use < and > button to move the wheel and the STOP button to stop the wheel from moving
- Find the 0.6 arcsec slit position
2a - From the OS:
- click on the MORE... button and enable "draw RTD object"
- in an wsofi Xterm type: isosCmd long_slit_0.6
2b - with the handset tool
- change the speed to 20
- Align the slit and the drawing within 1 pixel over the entire detector
- Do a Fall Back Init
3 - From the OS control panel
- run SOFI_spec_tecAlignSlit template from BOB
- if mis-alignment is more than 1 pixel: accept changing encoder position, and repeat process
- When mis-alignment is better than 1 pixel, do not change encoder position
- ReDo the Fall Back Init
4 - Resume normal operations
Don't forget to report PB and SOFI LogMon error messages in Remedy!
| Send
comments to: NTT Webmasters <nttweb@www.ls.eso.org> Last Update: MMM DD, YYYY (WHO) |