After a TCS cool start or a reinitialization of M2 ,
M2 is in a wrong position producing an important COMA

It is MANDATORY to

initialize M1 & M2

as described in startup check list (page 4  item 91 at the moment).

It is also advisable at the beginning of the night to check that 
M2Y is closer from 0.5 than from 1.75 .