Performance of AO system:
Problems with actuators of the M1 cell affect the
efficiency of the Active Optics system and should be therefore
identified/reported as soon as they appear.
To detect a misfunctioning of one of the actuators:
You can check yourself which actuator has the highest error by looking
at the following log file on wt5tcs:
$VLTDATA/ENVIRONMENTS/lt5m1/output/m1Setting.log
Go to the end of the file and you will get the relevant information
concerning the latest force setting:
example:
98-06-01 21:08:36
----- Absolute force setting started ----- ZD = 1.0 deg, dZD/dt = 0.0000000
rad/sec
98-06-01 21:13:44
SET: 3 par (296.6 sec), 0 seq (0.0 sec) || 9 act, 4.4 N, 1.00 iter. | highest:
254.7 N,
err. delay: -0.025 sec, 5 worst
act.: 23, 29, 7, 50, 63, err. sum: -199.6 N, act. lim: 1
fixed points: errors (7,29,50) = 109.9 N, 138.1 N, -8.1 N | current (660.6,
632.4, 778.6)
>From this log, it appears that the highest error is due
to actuator 23 with a force error of 254.7 N.