*** MIDAS logfile (05SEPpl1.2) *** We, 03 Oct 2007 15:55:57 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** We, 03 Oct 2007 15:56:11 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#46 TAKEN ON 071003 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 349.52 stddev = 1.98 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_46_071003 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 2.17 1601.9 1602.1 789.2 0.12 0.13 2.03 2 4.34 3191.7 3191.0 1593.7 -0.19 -0.21 2.00 3 8.67 6388.1 6388.4 3163.9 -0.07 -0.06 2.02 4 13.00 9577.6 9577.6 4751.7 -0.10 -0.10 2.02 5 19.51 14372.2 14374.0 7093.0 -0.06 -0.05 2.03 6 26.01 19169.8 19170.3 9530.1 -0.01 -0.01 2.01 7 32.51 23973.0 23973.5 11753.1 0.03 0.03 2.04 8 43.34 31979.9 31979.9 15218.8 0.09 0.08 2.10 9 54.17 39986.9 39983.7 18730.7 0.12 0.11 2.13 10 65.01 47964.8 47962.1 22441.8 0.08 0.07 2.14 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3437 to 102904 e- Average count rate measured: 737 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.15 +/- 0.02 e-/ADU RON = 4.24 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.000 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.12/-0.20 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay