*** MIDAS logfile (05SEPpl1.2) *** Tu, 13 Feb 2007 13:43:45 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Tu, 13 Feb 2007 13:43:59 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#46 TAKEN ON 070213 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 349.10 stddev = 1.97 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_46_070213 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 2.17 1710.9 1711.3 850.7 0.11 0.12 2.01 2 4.34 3410.4 3409.9 1701.3 -0.18 -0.18 2.00 3 8.67 6825.3 6825.4 3379.8 -0.07 -0.07 2.02 4 13.00 10235.7 10235.3 5050.2 -0.08 -0.09 2.03 5 19.51 15358.0 15357.8 7608.2 -0.05 -0.05 2.02 6 26.01 20485.1 20486.2 10005.5 -0.01 -0.01 2.05 7 32.51 25616.4 25618.3 12412.6 0.03 0.04 2.06 8 43.34 34173.7 34175.0 16438.0 0.09 0.09 2.08 9 54.17 42716.5 42718.6 20057.2 0.09 0.09 2.13 10 65.01 51246.0 51247.6 23747.0 0.06 0.06 2.16 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3684 to 110326 e- Average count rate measured: 788 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.15 +/- 0.02 e-/ADU RON = 4.23 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.001 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.12/-0.18 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay