*** MIDAS logfile (05SEPpl1.2) *** Th, 20 Jul 2006 16:37:02 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Th, 20 Jul 2006 16:37:16 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#46 TAKEN ON 060720 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 348.93 stddev = 2.00 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_46_060720 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 3.08 1573.9 1574.0 769.7 0.10 0.11 2.04 2 6.16 3138.6 3138.4 1553.0 -0.17 -0.18 2.02 3 12.31 6282.8 6283.1 3127.7 -0.07 -0.07 2.01 4 18.47 9420.7 9421.6 4651.2 -0.11 -0.10 2.03 5 27.70 14138.1 14138.0 6979.8 -0.05 -0.05 2.03 6 36.93 18859.7 18856.7 9294.1 -0.01 -0.02 2.03 7 46.16 23584.4 23584.4 11375.8 0.04 0.04 2.07 8 61.54 31458.1 31456.2 15060.6 0.08 0.07 2.09 9 76.93 39341.6 39341.6 18918.7 0.12 0.13 2.08 10 92.31 47186.0 47184.7 22061.7 0.07 0.07 2.14 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3344 to 100264 e- Average count rate measured: 511 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.12 +/- 0.02 e-/ADU RON = 4.25 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.002 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.13/-0.18 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay