*** MIDAS logfile (05SEPpl1.2) *** Fr, 21 Apr 2006 13:56:22 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Fr, 21 Apr 2006 13:56:36 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#46 TAKEN ON 060421 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 348.15 stddev = 2.00 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_46_060421 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 3.08 1634.4 1634.5 814.6 0.11 0.11 2.01 2 6.16 3261.3 3261.5 1628.5 -0.13 -0.14 2.00 3 12.31 6525.1 6525.8 3244.3 -0.10 -0.09 2.01 4 18.47 9789.5 9788.8 4777.5 -0.09 -0.10 2.05 5 27.70 14687.9 14688.4 7118.8 -0.06 -0.06 2.06 6 36.93 19593.1 19593.5 9616.9 -0.01 -0.01 2.04 7 46.16 24499.3 24498.8 11880.9 0.02 0.01 2.06 8 61.54 32688.3 32690.8 15584.4 0.09 0.09 2.10 9 76.93 40855.2 40856.4 19441.0 0.08 0.08 2.10 10 92.31 49036.1 49039.8 22689.0 0.09 0.10 2.16 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3507 to 105213 e- Average count rate measured: 531 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.15 +/- 0.02 e-/ADU RON = 4.30 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.004 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.11/-0.13 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay