*** MIDAS logfile (05SEPpl1.2) *** Fr, 17 Mar 2006 18:53:52 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Fr, 17 Mar 2006 18:54:06 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#46 TAKEN ON 060317 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 348.11 stddev = 2.00 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_46_060317 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 3.08 1664.0 1664.3 836.2 0.12 0.10 1.99 2 6.16 3318.5 3319.8 1675.8 -0.16 -0.14 1.98 3 12.31 6641.9 6642.0 3241.2 -0.08 -0.09 2.05 4 18.47 9961.4 9961.5 4976.7 -0.10 -0.10 2.00 5 27.70 14949.1 14948.6 7223.2 -0.05 -0.05 2.07 6 36.93 19940.6 19939.3 9746.2 -0.00 -0.01 2.05 7 46.16 24934.5 24934.0 12010.5 0.03 0.03 2.08 8 61.54 33262.0 33264.5 15965.5 0.08 0.09 2.08 9 76.93 41582.9 41580.4 19495.9 0.09 0.09 2.13 10 92.31 49888.4 49889.1 23641.6 0.07 0.07 2.11 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3538 to 106061 e- Average count rate measured: 540 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.13 +/- 0.01 e-/ADU RON = 4.26 +/- 0.03 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.003 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.11/-0.15 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay