*** MIDAS logfile (03SEPpl1.2) *** We, 08 Dec 2004 19:58:16 Page 1 *** MIDAS logfile (vers. 03SEPpl1.2) *** We, 08 Dec 2004 19:58:32 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#45 TAKEN ON 041208 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 350.07 stddev = 2.07 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_45_041208 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 3.08 1674.0 1674.0 857.5 0.07 0.09 1.95 2 6.16 3341.8 3341.0 1708.4 -0.09 -0.09 1.96 3 12.31 6680.4 6680.6 3339.8 -0.11 -0.11 2.00 4 18.47 10023.1 10023.8 5009.1 -0.08 -0.07 2.00 5 27.70 15036.3 15037.6 7491.6 -0.06 -0.05 2.01 6 36.93 20059.2 20060.8 9815.6 -0.01 0.00 2.04 7 46.16 25078.0 25078.6 12106.1 0.01 0.01 2.07 8 61.54 33471.8 33475.6 16051.3 0.11 0.12 2.09 9 76.93 41813.3 41814.9 19573.9 0.05 0.05 2.14 10 92.31 50209.3 50177.3 23562.8 0.12 0.05 2.13 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3591 to 107661 e- Average count rate measured: 543 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.14 +/- 0.02 e-/ADU RON = 4.43 +/- 0.03 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.002 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.12/-0.11 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay