*** MIDAS logfile (05SEPpl1.2) *** Tu, 02 Jan 2007 12:33:28 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Tu, 02 Jan 2007 12:33:42 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#45 TAKEN ON 070102 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 355.04 stddev = 1.99 FIERA temperature = 273.15 K There were 2 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_45_070102 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 2.17 1724.8 1724.5 822.8 0.14 0.13 2.10 2 4.34 3439.5 3438.8 1628.0 -0.18 -0.19 2.11 3 8.67 6883.3 6883.8 3290.3 -0.11 -0.10 2.09 4 13.00 10324.5 10324.3 4989.9 -0.12 -0.12 2.07 5 19.51 15493.6 15493.9 7454.4 -0.08 -0.08 2.08 6 26.01 20668.1 20668.4 10036.0 -0.03 -0.03 2.06 7 32.51 25847.1 25846.8 12454.0 0.01 0.01 2.08 8 43.34 34493.3 34493.1 16358.0 0.10 0.10 2.11 9 54.17 43119.9 43124.5 20413.5 0.11 0.12 2.11 10 65.01 51768.3 51771.4 24105.4 0.16 0.16 2.15 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3683 to 110539 e- Average count rate measured: 795 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.14 +/- 0.01 e-/ADU RON = 4.25 +/- 0.03 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.004 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.16/-0.18 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay