*** MIDAS logfile (05SEPpl1.2) *** We, 29 Mar 2006 15:10:00 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** We, 29 Mar 2006 15:10:15 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#45 TAKEN ON 060329 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 351.82 stddev = 2.08 FIERA temperature = 273.15 K There were 2 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_45_060329 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 3.08 1649.8 1650.1 777.7 0.14 0.12 2.12 2 6.16 3291.6 3291.5 1553.3 -0.16 -0.17 2.12 3 12.31 6588.4 6588.7 3148.0 -0.11 -0.11 2.09 4 18.47 9882.3 9882.8 4746.6 -0.13 -0.12 2.08 5 27.70 14831.2 14831.3 7165.2 -0.08 -0.07 2.07 6 36.93 19784.6 19783.0 9706.4 -0.03 -0.04 2.04 7 46.16 24741.4 24740.9 12381.1 0.01 0.01 2.00 8 61.54 33012.6 33013.3 15709.7 0.08 0.09 2.10 9 76.93 41284.3 41285.2 19750.1 0.12 0.13 2.09 10 92.31 49557.6 49557.3 23000.5 0.16 0.16 2.15 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3507 to 105343 e- Average count rate measured: 536 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.13 +/- 0.03 e-/ADU RON = 4.43 +/- 0.06 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.007 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.16/-0.17 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay