*** MIDAS logfile (03SEPpl1.2) *** We, 28 Sep 2005 19:03:35 Page 1 *** MIDAS logfile (vers. 03SEPpl1.2) *** We, 28 Sep 2005 19:04:36 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rD2 TAKEN ON 050928 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 346.56 stddev = 4.30 FIERA temperature = 290.6 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rD2_050928 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 1.00 787.5 786.5 667.4 0.10 0.08 1.18 2 2.00 1579.8 1579.3 1386.7 -0.06 -0.03 1.14 3 4.00 3165.4 3166.1 2519.9 -0.12 -0.11 1.26 4 6.00 4753.2 4753.4 3764.0 -0.10 -0.09 1.26 5 9.00 7137.2 7136.3 5685.6 -0.04 -0.05 1.26 6 12.00 9520.2 9519.0 7585.0 -0.03 -0.04 1.26 7 15.00 11906.9 11905.7 9311.2 0.01 0.00 1.28 8 20.00 15884.6 15883.9 12932.0 0.05 0.05 1.23 9 25.00 19864.4 19863.7 15793.5 0.09 0.08 1.26 10 30.00 23844.2 23844.2 18691.9 0.11 0.11 1.28 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 998 to 30235 e- Average count rate measured: 794 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.27 +/- 0.01 e-/ADU RON = 5.46 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = -0.008 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.11/-0.12 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay