*** MIDAS logfile (05SEPpl1.2) *** We, 12 Jul 2006 23:59:18 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Th, 13 Jul 2006 00:00:29 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rC2 TAKEN ON 060712 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 273.81 stddev = 5.57 FIERA temperature = 288.0 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rC2_060712 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 1.06 1735.3 1736.4 1426.5 -0.04 -0.05 1.22 2 2.12 3400.0 3399.7 2773.7 0.15 0.14 1.23 3 4.25 6696.3 6695.4 5401.7 -0.18 -0.18 1.24 4 6.38 10012.0 10011.7 8015.8 -0.11 -0.11 1.25 5 9.57 14983.6 14984.7 12055.1 -0.07 -0.06 1.24 6 12.76 19975.8 19975.8 15954.4 0.05 0.05 1.25 7 15.95 24954.4 24954.6 19943.9 0.07 0.08 1.25 8 21.27 33255.5 33256.0 26154.2 0.10 0.11 1.27 9 26.59 41534.5 41533.6 32551.5 0.07 0.07 1.28 10 31.91 49767.2 49767.7 38241.2 -0.05 -0.04 1.30 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 2248 to 64453 e- Average count rate measured: 1558 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.30 +/- 0.01 e-/ADU RON = 7.21 +/- 0.05 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.055 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.15/-0.18 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay