*** MIDAS logfile (03SEPpl1.2) *** Su, 13 Feb 2005 18:02:24 Page 1 *** MIDAS logfile (vers. 03SEPpl1.2) *** Su, 13 Feb 2005 18:03:38 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rC2 TAKEN ON 050213 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 337.35 stddev = 5.80 FIERA temperature = 290.9 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rC2_050213 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 1.00 993.3 992.9 845.8 0.07 0.04 1.17 2 2.00 1912.3 1911.7 1653.0 -0.05 -0.06 1.16 3 4.00 3752.0 3751.6 3064.8 -0.06 -0.07 1.22 4 6.00 5590.2 5590.5 4607.8 -0.08 -0.07 1.21 5 9.00 8351.1 8351.2 6809.0 -0.06 -0.05 1.23 6 12.00 11113.4 11112.6 8998.4 -0.03 -0.02 1.24 7 15.00 13877.3 13876.9 11241.8 0.00 0.00 1.23 8 20.00 18486.2 18486.1 15240.0 0.04 0.05 1.21 9 25.00 23096.7 23096.3 18592.7 0.08 0.08 1.24 10 30.00 27703.8 27704.2 22100.0 0.09 0.09 1.25 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 1241 to 34610 e- Average count rate measured: 920 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.25 +/- 0.01 e-/ADU RON = 7.25 +/- 0.05 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.081 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.09/-0.08 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay