*** MIDAS logfile (05SEPpl1.2) *** We, 27 Sep 2006 18:14:23 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** We, 27 Sep 2006 18:15:17 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rB2 TAKEN ON 060927 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 277.56 stddev = 4.44 FIERA temperature = 288.2 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rB2_060927 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 1.06 2019.3 2020.6 1602.4 0.03 0.03 1.26 2 2.13 3896.7 3897.6 4868.0 0.10 0.11 0.80 3 4.25 7609.2 7608.4 5928.9 -0.33 -0.34 1.28 4 6.38 11351.9 11351.2 8864.4 -0.24 -0.24 1.28 5 9.57 16966.4 16965.5 13145.0 -0.14 -0.15 1.29 6 12.76 22609.5 22611.6 17479.3 0.03 0.03 1.29 7 15.95 28245.7 28246.3 22025.8 0.10 0.10 1.28 8 21.27 37645.0 37644.5 28568.0 0.19 0.18 1.32 9 26.59 47016.3 47016.7 35292.2 0.18 0.18 1.33 10 31.91 56336.9 56337.1 41559.7 0.09 0.09 1.36 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 2768 to 77206 e- Average count rate measured: 1759 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.37 +/- 0.02 e-/ADU RON = 6.09 +/- 0.09 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.088 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.19/-0.34 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay