*** MIDAS logfile (05SEPpl1.2) *** We, 30 Jan 2008 16:35:08 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** We, 30 Jan 2008 16:35:26 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rB1 TAKEN ON 080130 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 225.73 stddev = 5.88 FIERA temperature = 288.0 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rB1_080130 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 4.25 1741.7 1741.2 1385.9 0.14 0.13 1.26 2 8.51 3450.2 3450.4 2833.4 -0.11 -0.11 1.22 3 17.02 6867.3 6867.6 5252.7 -0.23 -0.23 1.31 4 25.53 10292.6 10293.1 7846.5 -0.19 -0.19 1.31 5 38.29 15442.2 15442.7 11601.8 -0.09 -0.09 1.33 6 51.06 20597.5 20597.7 15287.6 -0.01 -0.01 1.35 7 63.83 25761.5 25761.5 18862.3 0.07 0.07 1.37 8 85.10 34371.5 34370.8 24391.4 0.16 0.16 1.41 9 106.38 42956.9 42955.1 29590.4 0.16 0.15 1.45 10 127.66 51520.5 51522.2 34464.0 0.11 0.12 1.49 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 2601 to 76942 e- Average count rate measured: 403 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.49 +/- 0.03 e-/ADU RON = 8.78 +/- 0.15 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.065 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.16/-0.23 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay