*** MIDAS logfile (03SEPpl1.2) *** Fr, 14 Oct 2005 16:52:37 Page 1 *** MIDAS logfile (vers. 03SEPpl1.2) *** Fr, 14 Oct 2005 16:53:42 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rA2 TAKEN ON 051014 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 359.82 stddev = 3.85 FIERA temperature = 291.5 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rA2_051014 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 1.00 1044.7 1044.6 866.3 -0.02 -0.04 1.21 2 2.00 2005.5 2004.5 1625.5 0.00 -0.02 1.23 3 4.00 3925.3 3925.2 3184.4 0.01 0.02 1.23 4 6.00 5845.7 5845.1 4714.7 0.02 0.02 1.24 5 9.00 8724.2 8724.3 6956.8 0.01 0.02 1.25 6 12.00 11605.4 11605.2 9259.1 0.02 0.03 1.25 7 15.00 14484.4 14483.8 11627.4 0.02 0.02 1.25 8 20.00 19281.4 19282.2 15178.7 0.00 0.02 1.27 9 25.00 24074.4 24074.5 18959.2 -0.01 -0.01 1.27 10 30.00 28859.4 28861.0 23085.7 -0.06 -0.05 1.25 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 1319 to 36431 e- Average count rate measured: 960 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.26 +/- 0.01 e-/ADU RON = 4.85 +/- 0.02 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.091 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.03/-0.05 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay