*** MIDAS logfile (05SEPpl1.2) *** We, 03 Jan 2007 16:05:57 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** We, 03 Jan 2007 16:06:15 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rA1 TAKEN ON 070103 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 266.96 stddev = 4.66 FIERA temperature = 288.2 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rA1_070103 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 4.25 1697.5 1697.7 1377.9 -0.10 -0.09 1.23 2 8.51 3375.5 3375.3 2730.5 0.08 0.08 1.24 3 17.02 6725.5 6726.1 5299.6 0.11 0.12 1.27 4 25.53 10075.0 10075.7 7894.8 0.11 0.12 1.28 5 38.30 15101.9 15102.2 11591.0 0.13 0.13 1.30 6 51.06 20119.8 20120.2 15212.4 0.10 0.10 1.32 7 63.83 25138.3 25136.3 18788.6 0.08 0.07 1.34 8 85.10 33478.5 33481.0 24257.6 -0.01 -0.01 1.38 9 106.38 41778.6 41782.1 29338.2 -0.16 -0.16 1.42 10 127.66 50036.0 50035.6 34023.1 -0.34 -0.35 1.47 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 2490 to 73396 e- Average count rate measured: 393 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.47 +/- 0.03 e-/ADU RON = 6.84 +/- 0.12 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.071 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.13/-0.35 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay