*** MIDAS logfile (05SEPpl1.2) *** Th, 20 Jul 2006 17:43:32 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Th, 20 Jul 2006 17:45:03 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#rA1 TAKEN ON 060720 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 226.16 stddev = 4.95 FIERA temperature = 288.4 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_rA1_060720 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 4.25 1766.3 1764.7 1474.4 -0.03 -0.07 1.20 2 8.51 3492.2 3493.6 2753.8 -0.03 0.05 1.27 3 17.02 6946.8 6946.4 5401.0 0.05 0.06 1.29 4 25.53 10401.2 10401.9 8010.5 0.08 0.09 1.30 5 38.30 15584.8 15583.3 11849.0 0.11 0.09 1.32 6 51.06 20763.7 20763.7 15674.9 0.09 0.09 1.32 7 63.83 25942.8 25943.0 19040.8 0.09 0.09 1.36 8 85.10 34555.1 34555.2 24610.5 0.03 0.02 1.40 9 106.38 43125.9 43122.5 29795.5 -0.10 -0.12 1.45 10 127.66 51648.8 51651.2 34471.6 -0.29 -0.29 1.50 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 2639 to 77204 e- Average count rate measured: 405 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 1.49 +/- 0.03 e-/ADU RON = 7.39 +/- 0.14 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.102 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.10/-0.29 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay