*** MIDAS logfile (05SEPpl1.2) *** Sa, 11 Feb 2006 13:58:47 Page 1 *** MIDAS logfile (vers. 05SEPpl1.2) *** Sa, 11 Feb 2006 13:59:38 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#31 TAKEN ON 060211 IN normcd MODE ========================================================== BIAS ==== 5 biases at start test: average = 564.18 stddev = 2.24 FIERA temperature = 273.15 K There were 0 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_normcd_31_060211 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 4.31 1241.2 1241.2 444.2 -0.05 -0.02 2.79 2 8.63 2444.9 2443.7 862.3 0.06 0.03 2.84 3 17.25 4843.5 4843.5 1751.9 0.05 0.05 2.76 4 25.87 7239.3 7239.4 2551.8 0.00 0.01 2.84 5 38.80 10833.0 10834.2 3859.3 -0.02 -0.01 2.81 6 51.73 14430.0 14428.7 4996.1 -0.02 -0.02 2.89 7 64.66 18025.6 18025.5 6276.5 -0.02 -0.02 2.87 8 86.21 24020.4 24018.9 8518.8 -0.01 -0.02 2.82 9 107.76 30017.7 30014.3 10682.4 0.00 -0.01 2.81 10 129.31 36012.0 36009.7 12598.2 -0.00 -0.00 2.86 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 3528 to 102366 e- Average count rate measured: 278 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.84 +/- 0.02 e-/ADU RON = 6.37 +/- 0.04 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.153 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.06/-0.03 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay