![[ ESO ]](/images/eso-logo.gif) |
 |
WFI
Aquisition
|
Imaging Acquistion Procedures
|
Simple Preset
WFI_img_acq_Preset
This is the simplest and most commonly used acquisition template which
does the following:
- points the telescope to the required field
- puts the correct filter in the beam
- aquires a guidestar
P2PP panel with
typical parameters
The above example shows a simple preset template to track the
target with the V/89 filter. This assumes that your first science
exposure will also be taken with the V/89 filter to minimise overheads
with changing filters.
Move to Gap
WFI_img_acq_MoveToGap
This template is used when you want to move a bright star into one of
the inter-chip gaps, or if you wish to place a particular star on a
particular pixel (discerned from the following diagram and table of the
WFI mosaic. It invokes the following steps:
- points the telescope to the required field
- puts the correct filter in the beam
- aquires a guidestar
- takes an exposure with Exposure time seconds
- reads out the CCD and transfers the data
- the current coordinates of the target star are entered into a
popup window
This must be clearly indicated on the finder chart for SM observations
- the desired coordinates of the target star are entered into a
popup window
These must be given in the README file for SM observations
- you may then select to do one of the following:
- perform the offset and take another image to check the offset (i.e. repeat from step 4)
- perform the offset and move onto the science exposures (i.e. you trust the offset and are not too worried about exact positioning)
- do not perform the offset and move onto the science exposures (i.e. the star will remain where it is in the aquisition image)
- abort the OB
What you choose will depend on exactly how precise you want the
positioning to be. Usually the initial offset (first iteration)
will put the star within 10 pixels of the requested pixel
coordinates. Subsequent iterations will get it within a few
pixels, but the chances of it actually falling exactly on
the same pixel are not high.
One should allow ~2 minutes + exposure time for each iteration.
P2PP panel
with typical parameters
The above example shows an acquisition template to preset the
telescope, put the V/89 filter in the beam, start the autoguider and
take a 10 second acquisition image. The rest of the information
required for this procedure (initial and final x,y coordinates of the
star, whether you want to iterate or not) are entered into popup
windows.
Move to Pixel
WFI_img_acq_MoveToPixel
This template is used when you want to place a particular star on a
particular pixel (discerned from the following diagram and table of the
WFI mosaic. It invokes the following steps:
- points the telescope to the required field
- puts the correct filter in the beam
- aquires a guidestar
- takes an exposure with Exposure time seconds
- reads out the CCD and transfers the data
- the current coordinates of the target star are entered into a
popup window
This must be clearly indicated on the finder chart for SM observations
- the desired coordinates of the target star are read from the template.
- you may then select to do one of the following:
- perform the offset and take another image to check the offset (i.e. repeat from step 4)
- perform the offset and move onto the science exposures (i.e. you trust the offset and are not too worried about exact positioning)
- do not perform the offset and move onto the science exposures (i.e. the star will remain where it is in the aquisition image)
- abort the OB
What you choose will depend on exactly how precise you want the
positioning to be. Usually the initial offset (first iteration)
will put the star within 10 pixels of the requested pixel
coordinates. Subsequent iterations will get it within a few
pixels, but the chances of it actually falling exactly on
the same pixel are not high.
One should allow ~2 minutes + exposure time for each iteration.
P2PP panel
with typical parameters
The above example shows an acquisition template to preset the
telescope, put the V/89 filter in the beam, start the autoguider and
take a 10 second acquisition image. The desired position of the
star is pixel x,y=4150,3950 near the center of the mosaic.
The actual x,y coordinates of the star are entered into a popup
window. The operator iterates until the star is within 10 pixels
of the desired position.
Send comments to : ls-wfi
Last modified: Thu 19 Oct 2006 |
![[Observing]](/images/icon-observing.gif) ![[ESO La Silla]](/images/icon-lasilla.gif) ![[The SciOps Home Page]](/images/icon-up.gif) ![[ESO]](/images/icon-home.gif) ![[Index]](/images/icon-index.gif) ![[Search]](/images/icon-search.gif) ![[Help]](/images/icon-help.gif) ![[News]](/images/icon-whatsnew.gif) |