On the basis of this observation and a second
(FEROS.2003-11-15T03:49:49.307.fits) in which an equally good
efficiency was
achieved,
we assume that FEROS is performing very close to its theoretically
expected best.
Hiedelberg ETC calculations for HR718
The Hidelberg ETC give the results tabulated in table 1 for HR718, both
for the default parameters of the ETC and the actual parameters
measured during the FEROS.2003-11-15T03:46:08.507 exposure.
Table 1: Expected S/N calculated with the Hiedelberg ETC. For
the Default
Parameters only the V magnitude (4.28mag), the spectra-type (B
since HR918 is a B9III) and the exposure time (120sec) are adjusted
from the default values set by the ETC. For the Actual Parameters in
addition to the above the following settings are made: the moon
brightness to dark, the seeing to 0.95 arcsec, the airmass to 1.27, the
temperature to 12.5°C, the atmospheric pressure to 772 hPa, the
humidity to 23%, the CCD ReadOut Noise to 5.0 electrons
Measured S/N
The S/N measured in the spectrum.
|
U
|
B
|
V
|
R
|
I
|
| Standard reduced spectrum using snrUBVRI.prg |
5
|
283
|
288
|
217
|
174
|
| Standard reduced spectrum using snrscanUBVRI.prg
|
5.6
|
857.7
|
731.3
|
661.1
|
452.7
|
| Non Flatfielded spectrum using snrscanUBVRI.prg
|
36.6
|
729.6
|
742.1
|
612.1
|
157.6
|
Table 2: Measured S/N calculated. The snrscanUBVRI.prg
script calls the snrscan.prg
MIDAS script of the FEROS-DRS. The snrUBVRI.prg and sncscan.prg scripts
just mentioned call the snr.prg
MIDAS script
of the FEROS-DRS for the actual S/N calculation.
The snrUBVRI.prg script calculates the S/N for each reference filter
(UBVRI) using intervals of 7, 10, 10, 18 and 16 nm respectively
centered on the central wavelengths of the filters (361, 441, 551, 658
and 806 nm).
The snrscanUBVRI.prg script scans the S/N over a range of wavelengths
using a interval of 4nm (which includes approximately 135 data points)
to calculate the S/N to find the maximum S/N in this region. The
intervals are in general offset from the central wavelengths of the
UBVRI filters in order to sample the spectrum in the middle of the
blase function of the relevant order, since of course the S/N is a
function of where on the blaze function of each order the measurement
is made.
The snrscanUBVRI.prg script is thus MUCH less sensitive to
absorption/emission lines which strongly bias the S/N calculation made
by snr.prg.
Discussion
The S/N for BVRI computed using the snrscanUBVRI.prg script on the
FlatFielded spectrum compare quite favourably with the predictions from
the Heidelberg ETC. The S/N for U does not, but this is to be
expected because the current Calibration Unit delivers almost no light
at this wavelength (i.e. the bluest order), hence the S/N in the
Flatfielded spectrum for U is dominated by the devision by the
Flatfield with
zero signal.
We see from the S/N calculations on the Non Flatfielded spectrum using
the snrscanUBVRI.prg script that the S/N in U is considerably better in
fact, though still somewhat less than predicted.