*** MIDAS logfile (vers. 97NOV) *** Su, 08 Sep 2002 15:50:46 Page 1 *** MIDAS logfile (vers. 97NOV) *** Su, 08 Sep 2002 15:52:17 Page 2 ========================================================== SUMMARY STANDARD TEST CCD#60 TAKEN ON 020908 IN blow MODE ========================================================== BIAS ==== 5 biases at start test: average = 210.50 stddev = 1.81 There were 1 hot pixels/columns detected TRANSFER FUNCTION AND LINEARITY DATA ==================================== Table : Std_blow_60_020908 Sequence Exp_tim1 Med_cnt1 Med_cnt2 Variance Frc_cnt1 Frc_cnt2 el_adu1 -------- --------- --------- --------- --------- --------- --------- --------- 1 2.00 638.8 639.0 264.7 0.27 0.26 2.41 2 4.00 1256.8 1256.5 509.5 -0.44 -0.47 2.47 3 8.00 2509.4 2509.3 1037.0 -0.13 -0.14 2.42 4 16.00 5007.5 5007.2 2048.1 -0.13 -0.13 2.44 5 32.00 10015.1 10015.7 3999.1 0.00 0.01 2.50 6 52.00 16287.2 16286.7 6372.8 0.12 0.12 2.56 7 72.00 22549.7 22549.6 8691.2 0.13 0.14 2.59 8 92.00 28806.8 28804.9 10951.7 0.12 0.12 2.63 9 112.00 35056.6 35054.6 12819.1 0.09 0.10 2.73 10 130.00 40641.4 40643.4 14868.7 -0.03 -0.01 2.73 -------- --------- --------- --------- --------- --------- --------- --------- Dynamic range explored: from 1745 to 111025 e- Average count rate measured: 313 ADU/sec. CONV. FACTOR AND RON ==================== C.Fact = 2.73 +/- 0.03 e-/ADU RON = 4.94 +/- 0.06 e- RMS SHUTTER ERROR ============= Average shutter error derived from fractional count rate = 0.038 sec LINEARITY ERROR =============== Average linearity error after shutter correct. = + 0.26/-0.46 % These errors represent maximum deviation in % from the average count rate after correction for shutter delay