MIDI Tools and Tips

MIDI spectrophotometric calibrators

This list contains the suitable spectrophotometric calibrators which should be used to calibrate the correlated flux of the targets observed with MIDI. The entries are shared elements between the MIDI consortium calibrator catalog and the Cohen or GBPP ISO calibrator lists. The Cohen list can be found in: http://www.iso.vilspa.esa.es/users/expl_lib/ISO/wwwcal/isoprep/cohen/templates/ and the GBPP list can be found in: http://www.iso.vilspa.esa.es/users/expl_lib/ISO/wwwcal/isoprep/gbpp/model/HD/.

NameRA (2000)Dec (2000)Orig.SpTParallax (mas)Prop. motion RA (arcsec/yr)Prop. motion Dec (arcsec/yr)V magH magJy @ 12 umQual.  Diam. (mas)Err. diam. (mas)
HD 1522 00 19 25.67 -08 49 26.1 iras K1.5III 11.26 0.73 -0.018 -0.029 3.558 1.028 13.144 3 * * 3.21 0.07 c
HD 4128 00 43 35.37 -17 59 11.8 iras K0III 34.04 0.82 0.232 0.036 2.04 -0.138 41.331 3 * * 5.04 0.07 c
HD 6805 01 08 35.39 -10 10 56.2 iras K1.5III 27.73 0.71 0.216 -0.138 3.450.985 14.6973 * * 3.2 0.07c
HD 11353 01 51 27.63 -10 20 06.1 iras K0III 12.59 0.85 0.035 -0.036 3.738 1.314 10.103 3 * * 2.7 0.07 c
HD 12524 02 01 42.38 -44 42 48.6 iras K5III 8.76 0.64 -0.03 -0.041 5.159 1.666 8.712 3 * * 2.530.07 c
HD 27697 04 22 56.09 +17 32 33.0 iras K0III 21.29 0.93 0.107 -0.028 3.764 1.684 6.986 3 * * 2.13 0.04 c
HD 37160 05 36 54.39 +09 17 26.4 iras K0IIIb 28.1 0.91 0.09 -0.304 4.09 1.769 6.466 3 * * 2.02 0.02 c
HD 49293 06 47 51.65 +02 24 43.8 iras K0IIIa 8.74 0.91 -0.021 -0.013 4.48 2.109 5.03 3 * * 1.88 0.05 c
HD 81420 09 25 24.04 -05 07 02.6 iras K5III 4.830.89-0.016 -0.015 5.593 1.29 5.148 3 * * 3.41 0.02 c
HD 95272 10 59 46.46 -18 17 55.6 iras K1III 18.71 1.03 -0.4650.1244.071.713 8.159 3 * * 2.19 0.05 c
HD 95578 11 01 49.67 -02 29 04.5 iras M0III 6.34 0.78 0.013 -0.038 4.737 * 15.278 3 * * 2.84 0.04 c
HD 101666 11 41 43.95 -32 29 57.9 iras K5III+... 7.59 0.76 -0.006 -0.033 5.222 1.927 6.356 3 * * 2.31 0.12 c
HD 102461 11 47 19.14 -57 41 47.4 iras K5III 3.97 0.61 -0.028 0.015 5.439 1.513 9.6 3 * * 2.96 0.18 c
HD 112213 12 55 19.43 -42 54 56.6 iras M0III 5.42 0.82 -0.041 -0.024 5.476 1.456 10.768 3 * * 2.95 0.18 c
HD 116870 13 26 43.17 -12 42 27.6 iras K5III 6.46 0.82 -0.135 -0.024 5.271 1.756 7.732 3 * * 2.44 0.12 c
HD 123139 14 06 40.95 -36 22 11.8 iras K0IIIb 53.52 0.79 -0.522 -0.522 2.06 -0.178 39.635 3 * * 5.17 0.02 c
HD 126927 14 28 41.72 -06 54 01.9 iras K5III 6.81 0.76 -0.021 -0.059 5.434 2.038 5.549 3 * * 2.14 0.12 c
HD 133774 15 06 37.60 -16 15 24.5 iras K5III 4.26 0.8 -0.045 -0.025 5.202 1.622 8.437 3 * * 2.77 0.4 c
HD 139127 15 38 03.21 -42 34 02.5 iras K4.5III 14.19 0.73 -0.146 0.055 4.354 1.211 12.328 3 * * 3.07 0.11 c
HD 151249 16 49 47.16 -59 02 29.0 iras K5III 10.41 0.69 0.041 -0.031 3.78 0.141 35.986 3 * * 5.34 0.11 c
HD 156277 17 21 59.48 -67 46 14.4 iras K2III 10.46 0.66 -0.026 0.002 4.78 2.076 5.151 3 * * 1.92 0.09 c
HD 163376 17 57 47.81 -41 42 58.7 iras M0III 5.96 0.71 -0.016 -0.01 4.897 0.904 17.129 3 * * 3.79 0.12 c
HD 169916 18 27 58.24 -25 25 18.1 iras K1IIIb 42.2 0.9 -0.043 -0.185 2.833 0.452 21.624 3 * * 3.75 0.04 c
HD 175775 18 57 43.80 -21 06 24.0 iras G8/K0II/III 8.76 0.99 0.035 -0.012 3.53 1.014 13.736 3 * * 3.26 0.23 c
HD 177716 19 06 56.41 -27 40 13.5 iras K1IIIb 27.09 1.48 -0.051 -0.251 3.32 0.686 17.99 3 * * 3.72 0.07 c
HD 178345 19 10 01.76 -39 20 26.9 iras K0II 6.42 0.9 0.002 -0.037 4.117 1.58 8.621 3 * * 2.46 0.13 c
HD 196321 20 36 43.63 -02 32 59.9 iras K5II 1.48 0.91 0.004 -0.001 4.903 1.312 11.578 3 * * 3.14 0.24 c
HD 196171 20 37 34.03 -47 17 29.4 iras K0IIICNvar... 32.21 0.75 0.056 0.07 3.116 0.904 14.897 3 * * 3.09 0.05 c
HD 196917 20 41 23.66 -31 35 53.8 iras M0III 7.78 0.78 0.103 -0.052 5.776 1.94 6.845 3 * * 2.15 0.12 c
HD 198048 20 49 28.96 -46 13 36.6 iras K5III 8.06 0.83 0.049 0.027 4.902 1.416 10.042 3 * * 2.86 0.11 c
HD 216032 22 49 35.50 -13 35 33.5 iras K5III 8.58 0.98 -0.015 -0.033 4.053 0.387 8.443 3 * * 4.89 0.11 c
HD 217902 23 04 39.63 -53 57 53.7 iras K5III 8.36 0.68 0.056 -0.11 5.385 1.982 5.96 3 * * 2.18 0.1 c
HD 218670 23 10 21.54 -45 14 48.2 iras K1III 17.63 0.92 0.137 -0.021 3.89 1.776 6.441 3 * * 2.06 0.07 c
HD 219449 23 15 53.49 -09 05 15.8 iras K0III 21.97 0.89 0.369 -0.012 4.21 1.863 5.927 3 * * 2.02 0.07 c
HD 219784 23 18 49.44 -32 31 55.3 iras G8III 18.24 0.8 0.021 -0.064 4.415 1.986 6.037 3 * * 2.04 0.07 c
HD 113996 13 07 10.73 +27 37 29.1 iras K5III 10.75 0.75 0.03 -0.077 4.795 1.425 10.002 3 * * 2.9 0.07 g
HD 120477 13 49 28.64 +15 47 52.5 iras K5.5III 13.29 0.81 -0.095 0.037 4.053 0.54 23.281 3 * * 4.46 0.02 g
HD 124897 14 15 39.67 +19 10 56.7 iras K1.5III 88.85 0.74 -1.098 -1.999 -0.04 -2.882 546.965 3 * * 19.26 0.01 g
HD 187642 19 50 47.00 +08 52 06.0 iras A7V 194.45 0.94 0.537 0.387 0.77 0.232 23.222 3 * * 3.22 0.01 g
HD 216131 22 49 00.19 +24 36 05.7 iras G8III 27.95 0.77 0.148 -0.036 3.513 1.436 26.688 3 28.53 3 2.37 0.04 g
 
You're on EPU
View live page